Rion VA-12 Quick Instruction Manual Download Page 18

 

18 

 

Window function

Hanning window 

Frequency span

20kHz (Acceleration),200Hz or 500Hz (Envelope) 

Number of analysis lines

Set up so that the frequency resolution becomes narrower than 1Hz 

    

Operation type

It is used if necessary 

 

 

An example of outer race defect of a bearing

The Ball Pass Frequency of Outer race can be observed at 77.8Hz. 

 

 

 

 

 

 

 

 

 

 

 

 

5.3 Measurement of natural frequency 

The  natural  frequencies  of  a  structure  can  be  measured  by  exciting  the  object.  Attach  an  accelerometer  to  the 

object, and excite it with an impulse hammer. In measurement, it is necessary to use the trigger function and the 

linear  average.  Refer  to  the  instruction  manual  of  VA-12  about  the  details  of  the  trigger  function.  When  an 

exciting point and an attached point of the accelerometer changes to the other position, the measured frequencies 

may change. In this case, all the measured frequencies are considered as natural frequencies. 

 

Fundamental settings 

Sensor selection

PV-57I (in usual case),   

A lighter accelerometer for example PV-91C (when the object is very small and light)   

High-pass filter

10 Hz 

Low-pass filter

20 kHz 

 

Analysis function

FFT Analyzer Mode 

Measurement data type

Acceleration 

Window function

Rectangular window 

Frequency span

5 kHz

Set up so that the whole natural frequencies are included

 

Number  of  analysis  lines

3200

Set  up  so  that  the  whole  decay  process  of  a  time  waveform  can  be 

observed

 

Operation type

Linear average

Average number

about 5 

FFT (envelope) 

Time waveform 

(acceleration)

 

Summary of Contents for VA-12

Page 1: ...ion 2 Measurement in Vibration Meter Mode 3 Measurement in Time Waveform Mode 4 Measurement in FFT Analyzer Mode 5 Examples of typical vibration measurement 5 1 Diagnosis of unbalance and misalignment...

Page 2: ...sis functions Vibration Meter Mode Time Waveform Mode and FFT Analyzer Mode The operation about common setups to each analysis function before starting measurement is explained in this section Inserti...

Page 3: ...7I Other accelerometers than PV 57I Optional accessory When the amplitude of vibration is too small or too large or the frequency is too high the PV 57I cannot measure them In that case an acceleromet...

Page 4: ...ching the accelerometer it is necessary to wait about 30 seconds until the influence of the impulsive vibration disappears Moreover it is necessary to care about the contact resonance frequency of the...

Page 5: ...selectable Input range setting Set the input range to the optimal setting The optimal setting is to use the lowest range where an overload does not occur The key changes to the higher range the key ch...

Page 6: ...ured data Store the data if necessary When the STORE key is pressed the data at that time is stored on SD card in VA 12 When in a paused state the fixed data is stored 3 Measurement in Time Waveform M...

Page 7: ...igher range the key changes to the lower range By changing input range an electric transient noise occurs and overload may be displayed In this case it is not an excessive input of vibration When an o...

Page 8: ...key The measurement changes to the paused state and a measured time waveform is fixed To resume the measurement press the PAUSE CONT key one more time Zooming the X axis and the Y axis of the graph d...

Page 9: ...STORE key is pressed the data at that time is stored on SD card in VA 12 When in a paused state the fixed data is stored 4 Measurement in FFT Mode Selecting the analysis function to FFT mode after com...

Page 10: ...hout repetition like a single pulse Hanning It is used for the usual measurement Flattop It is used for reading the amplitude correctly although the frequency resolution may be worse Selecting the mea...

Page 11: ...y span and the Number of analysis lines In order to determine the maximum frequency to analyze and the frequency resolution the frequency span and the number of analysis lines are set up The frequency...

Page 12: ...e average is not necessary since the vibration is steady The operation type is chosen as follows according to the measurement purpose Linear average It is a popular averaging type and is used to obtai...

Page 13: ...rum In Linear average or Maximum hold the operation stops when the average counter reaches to the average number and the FFT spectrum is fixed In Instantaneous measurement or Exponential average the o...

Page 14: ...is assumed that the cursor move symbol is displayed at first If the Graph zoom symbol is displayed at first press the SCALE EXPAND MOVE key to change the zoom mode Move the cursor to the position whe...

Page 15: ...d in VA 12 When in a paused state the fixed data is stored STORE key PAUSE CONT key Original graph Move the cursor to the position you want to expand Expand 4 Expand 8 Expand 16 Cursor Cursor SCALE EX...

Page 16: ...are investigated by Time Waveform Mode or FFT Analyzer Mode In unbalance condition only a shaft rotational frequency appears but in misalignment condition a shaft rotational frequency and its harmonic...

Page 17: ...udgment is abnormal the precise diagnosis is carried out In precise diagnosis the defected part can be predicted by FFT analysis of acceleration envelope if the information about the bearing to diagno...

Page 18: ...of VA 12 about the details of the trigger function When an exciting point and an attached point of the accelerometer changes to the other position the measured frequencies may change In this case all...

Page 19: ...e trigger ON Trigger level 1 8 2 8 Slope The trigger conditions are set in the submenu Measurement Press the MENU key and go into the submenu Measurement from the Menu List A measurement example of na...

Page 20: ...ddress is indicated at the upper right corner of display This store address means the address contained in a Store Name which was set up at the previous step The measured data can be stored in the ind...

Page 21: ...e the selected data is recalled and the character Recall is displayed at the upside center The recall address can be selected by keys Returning to the measurement state The START STOP key is pressed t...

Page 22: ...reen bitmap image Press both the MENU key and the ENT key simultaneously When the storing is started the indicator blinks red It disappears after completed Recalling the screen bitmap image Press both...

Page 23: ...s the SD card in VA 12 as a removable disk All stored files exist in the VA 12 folder The folders MAN_ include measured data files means 4 digits number The folder name MAN_ is same as the Store Name...

Page 24: ...following figure there are six data files in the folder MAN_9999 The extension names of the data files are RVD Copy required data files to another folder in a computer Copying BMP files The stored BM...

Page 25: ...The file open window appears as shown in the following figure In this window select the folder to import for example MAN_9999 In this stage since the file type is set to All Excel Files No items match...

Page 26: ...ining that the selected file is delimited After clicking the Open the Text Import Wizard Step 1 of 3 appears as shown in the following figure In this wizard select the Choose the file type that best d...

Page 27: ...ile After clicking the Next the Text Import Wizard Step 2 of 3 appears Check the checkbox of the Comma Then click the Finish Importing the data to Microsoft Excel After clicking the Finish the data ar...

Reviews: