2) Improper installation location.
Place where the temperature would elevate to 40
℃
or above (Adjacent to a
gas boiler and others)
Place with direct sunrays
Place with a high level of moist (A gas stove, a rice cooker and others)
Place with the risk of water spattering
Greasy area
Place where special chemicals (benzene, oil-based detergent and others)
51
Remote Controller Installation
1) Connection of the Remote controller
Do not plug the boiler until a power line of the remote controller is connected to
the boiler. Do not plug the boiler into the outlet until the installation of the remote
controller is completed.
Do not disassemble the remote controller. It could cause abnormal operation of
the boiler.
Power lines of the remote controller should be wired not to be influenced by direct heat.
The remote controller does not have the polarity.
1. Requirements for an Installation Location.
1) Install a remote controller on the wall at the height of 1.2~1.5m from the floor.
Also, the location provides a sufficient clearance for allowing of each access.
A living room or a main bed room could be suitable.
2. Power Connection of the Remote Controller.
Power lines of the remote controller must be a two-wire two-layer
vinyl chloride sheath copper wire and the aged power lines should
be exchanged. When the sheath is peeled off, it could lead to a
short circuit or current leakage, in turn deteriorating the boiler.
Do not tie up the power lines of the remote controller with other
230V AC power lines, or place them together in the underground
wire piping. Electric noise could arise.
When the remote controller is connected, Cover the power lines
with the insulating tape to prevent a short circuit or current leakage.
When the remote controller malfunctions due to the electromagnetic
wave noise, change the power lines of the remote controller to the
shield cable, which could shield the noise.
Caution