background image

21

To use reservation timer

5.

Please press 

 (Timer) button after time set.

6.

 Please press 

 to set the daytime

 

     temperature (H) and press  

to confirm.

7.

Please

     Boiler will start heating (CH).

Heating program is starting.

 press 

 to set the night

 

     temperature (L) and press  

to confirm.

Summary of Contents for WF-100B_EU

Page 1: ...se of explanation they may be partially different from actual appearance External appearance and specifications of the product are subject to change without notice for quality improvement Product warranty is included in the manual This product is subject to treatment of domestic waste and is to be discarded by the user according to the standards on plastic garbage bag and separate disposal and rec...

Page 2: ...wing cases 1 When failure is caused by injection of alien substances water beverage coffee toy etc into the product 2 When the product is damaged or functional failure occurs from external impact during installation or use 3 When exterior is damaged or deformed by organic solvents like thinner and benzene 4 When failure is caused by use of parts or consumables which are not standard products suppl...

Page 3: ...3 Block diagram of Rinnai Wi Fi boiler Communication network 3G 4G Internet 3G 4G Wi Fi Smart phone Wireless router HOME Rinnai server ...

Page 4: ...ontroller Heating ON OFF Wi Fi Timer Power Settings Outing Increase volume Decrease volume Switch heating method Hot water ON OFF Decrease heating temperature Increase heating temperature Increase hot water temperature Decrease hot water temperature ...

Page 5: ...lowing components User Manual Screws 2 ea for installation of indoor temperature controller Indoor temperature controller Indoor temperature controller Outing mode Heating mode Automatic mode Wi Fi Save mode Time Eco combustion Sleep mode Service mode Combustion Timer mode Hot water mode Hot water preheating Display part Timer setting Hot water temperature Heating temperature setting current ...

Page 6: ...f corresponding wireless router and internet service provider 6 Rinnai Wi Fi boiler only supports wireless routers with Wi Fi 2 4Ghz 7 Rinnai Wi Fi boiler supports IEEE802 11 b communication protocol Make sure to check whether the router supports IEEE802 11 b before installation 8 Only use letters and numbers for the name of Wi Fi connection characters like é may not be supported This device is ap...

Page 7: ... ⓑ ⓐ Please set present time Correct method of use Indoor temperature controller Time can only be set when heating and hot water mode are turned OFF Incorrect time will be displayed upon initial power connection and after long term power failure Follow the instructions above to set current time Please set the time for proper use of timer function When smart phone function is used current time is a...

Page 8: ... guidance is over 3 To confirm voice guidance language press ⓑ settings Voice guidance is starting Voice guidance is starting To change voice guidance language 1 Press ⓑ Settings for 3 seconds with the remote controller switched off 2 When the current language is displayed in the remote controller select the voice guidance language by usingⓒ increase heating temperature or decrease heating tempera...

Page 9: ...heating method button to change heating method Heating method cannot be switched in auto mode Please press the button after releasing auto mode The Wi Fi Remote controller allows the user to set the water flow temperature for the heating system ⓐ Start heating by indoor temperature When switched to Space heating mode Start heating by heating water temperature When switched to Flow temperature mode...

Page 10: ...ure by pressing ⓑ increase heating temperature or decrease heating temperature buttons The boiler is not operated when current temperature is higher than setting temperature ⓐ ⓑ Liquid crystal display when indoor temperature heating is used Heating is ON Heating temperature has changed Range of temperature setting for indoor temperature heating is between 5 C and 40 C ...

Page 11: ...ter temperature of the boiler for 10 seconds Heating temperature cannot be controlled in Auto mode and Sleep mode 4 Press ⓐ heating ON OFF button to turn heating OFF Liquid crystal display when floor heating is used Range of temperature setting for floor heating is between 50 C and 80 C Heating has been turned off Gas rates can be saved as energy efficiency of the boiler is highest in this mode EC...

Page 12: ...utomatically changed to 40 C the highest temperature possible Liquid crystal display when rapid heating is used with indoor temperature heating ⓐ ⓑ 1 Press ⓐ heating ON OFF button Heating is ON 2 Press ⓑ increase heating temperature and decrease heating temperature buttons at the same time Heating is set to highest temperature possible To stop rapid heating function change setting temperature duri...

Page 13: ...hot water temperature ⓐ ⓑ 1 Press ⓐ hot water ON OFF button Hot water is available Hot water temperature has changed Be careful as hot water temperature is high Hot water temperature can be set between 35 C and 60 C When changing from 55 C to 60 C turn water off and press increase hot water temperature button Warning ...

Page 14: ...ot used even if hot water function is turned ON It remains in hot water standby mode and does not consume gas When heating power button is pressed while using hot water function both functions can be used at the same time Heating cannot be done with only hot water turned ON Hot water and heating functions can be used at the same time by pressing heating ON OFF button while using hot water function...

Page 15: ...pears on the hot water display and preheating is turned ON To stop hot water preheating function open the hot water faucet or pressⓑ increase hot water temperature and decrease hot water temperature buttons at the same time To use hot water preheating ⓐ ⓑ 1 Press ⓐ hot water ON OFF button Hot water is available Preheating hot water is starting When hot water preheating is turned on Preheating hot ...

Page 16: ...nt heating and hot water Sensible temperature felt by the user may differ according to the environment of use This function adjusts combustion extinguishing time and limits heating temperature to save energy In save mode maximum temperature setting is limited to 20 C for indoor temperature heating and 60 C for floor heating Liquid crystal display when indoor temperature heating is done in auto mod...

Page 17: ...leep mode OFF This is convenient function that automatically adjusts indoor temperature for 6 hours after sleep mode is set to provide sound sleep Sensible temperature felt by the user may differ according to the environment of use Sleep mode is starting 17 To use modes ...

Page 18: ...ture cannot be modified The boiler enters a 4h loop as long as the function is enabled After 4 hours the boiler ignites and operates for 10 min at a flow temperature of 50 C only if the heating system temperature is below 25 C again during Liquid crystal display when Indoor temperature heating is used with outing Liquid crystal display when Floor heating is used with with outing 1 Press ⓐ outing b...

Page 19: ...hen the timer function is reused after a previous activation it starts with the last heating program that has been selected There are three basic lifestyle patterns for timer numbers which cannot be changed If you would like to newly configure your own lifestyle pattern can be used 1 Press ⓐ heating ON OFF button Heating is ON 2 Press ⓑ timer button 3 Use ⓑ timer button to set the wanted heating p...

Page 20: ...emperature or decrease heating temperature buttons to move the cursor to the wanted time and press ⓓ settings button to confirm To turn off the timer press ⓓ 4 Repeat the same method to set timer for the wanted time Once timer setting is completed timer heating is automatically started after a few seconds Please select heating time Heating program is starting ...

Page 21: ... press ⓑ Timer button after time set 6 Please press ⓒ to set the daytime ⓑ temperature H and press to confirm 7 Please Boiler will start heating CH Heating program is starting press ⓒ to set the night ⓑ temperature L and press to confirm ...

Page 22: ...ess ⓐ Wi Fi button again Wi Fi function will be stopped after is turned OFF Wi Fi is connecting Wi Fi is disconnected When the boiler is controlled on a smart phone application it can only be used when temperature controller is connected to Wi Fi Refer to the following page to download the application ...

Page 23: ...pp Store by searching with the keyword Mirai Mirai application is optimized for iOS and Android Please check the version of OS on your smart phone Supported versions Android from Gingerbread 2 3 iOS Some functions may not work properly when the application is used on other devices or tablets Mirai from iOS7 ...

Page 24: ... Proceed without entering phone number is selected you can enter user information on the following page without entering phone number 2 Read the terms of agreement of Rinnai app select ⓐ Agree and press ⓑ OK button ⓑ ⓐ If the GPS function of the smartphone is switched off during the registration procedure the GPS Notifications will not be available ⓐ ⓑ ⓐ ⓐ ⓑ ⓒ ⓑ NB during the registration procedur...

Page 25: ...s long ⓐ ⓑ ⓒ ⓔ ⓓ ⓐ 5 Press ⓐ Wi Fi button of temperature controller for 3 seconds to enter registration mode Registration can only be done when heating and hot water are turned OFF on temperature controller 6 Check the 4 digit unique ID displayed on the display window of temperature controller Registration mode is turned OFF after 10 minutes The following letters and numbers can appear on temperat...

Page 26: ...26 How to register for Android users 7 Select the wireless router to be used at home 8 Enter ⓐ Password of the wireless router set by the user and press ⓑ OK button ⓐ ⓑ ⓐ ...

Page 27: ...Android users 9 Select the item with 4 digit unique ID displayed on temperature controller Remote controller item type Rinnai 4 digit unique ID 123A Wi Fi registration is complete Start over from step 1 if registration fails 123A is changed according to each device 4 digituniqueID Registering ...

Page 28: ...e Wi Fi boiler If the GPS function of the smartphone is switched off during the registration procedure the GPS Notifications will not be available 1 Run the application 2 Read the terms of agreement of Rinnai app select ⓐ Agree and press ⓑ OK button ⓑ ⓐ ⓑ ⓐ ...

Page 29: ...one number 4 Enter ⓐ User nickname ⓑ Password ⓒ Question and answer to find lost password and press ⓓ to scan the boiler QR ⓔ code then press OK After pressing the button check the informations collected through QR code in particular verify the type of gas used In case it is required proceed with a manual introduction of data Password must be at least 4 characters long ⓐ ⓐ ⓑ ⓐ ⓑ ⓒ ⓔ ⓓ ⓐ ⓑ ⓒ ⓔ ⓔ ⓓ ...

Page 30: ...tion can only be done when heating and hot water are turned OFF on temperature controller 6 Check the 4 digit unique ID displayed on the display window of temperature controller Registration mode is turned OFF after 10 minutes The following letters and numbers can appear on temperature controller Run the Rinnai boiler application and select ID of temperature controller Numbers Letters 4 digituniqu...

Page 31: ... temperature controller Type of temperature controller display Rinnai 4 digit unique ID 8 Select ⓐ Wi Fi setting menu on the setting screen ⓐ ⓐ Rinnai_123A Rinnai_123A ai_123A A Rinnai 12 A A A Rinnai 123A Rinnai_123A Rinnai_123A 123A is changed according to each device 4 digit unique ID ...

Page 32: ...32 How to register for iOS users 10 Return to the application and press ⓐ OK button ⓐ 11 Select the wireless router to be used at home ...

Page 33: ...perature controller has been successfully registered How to register for iOS users 12 Enterⓐ Password of the wireless router set by the user and press ⓑ OK button Wi Fi registration is complete ⓐ ⓑ ⓐ Registering ...

Page 34: ...find your password using the question selected during registration If password is lost You can use the Wi Fi boiler after logging in 1 Enter the password selected during registration and press ⓑ OK button ⓐ ⓑ ⓐ ⓑ Password ...

Page 35: ...35 3 Enter new ⓐ Password and press ⓑ OK button You may now log in with the new password on the login screen Login ⓑ ⓐ Type in your password 4 16digts ...

Page 36: ...is automatically heated to allow for deep sleep Save energy and gas rates can be saved Reservation timer heating is operated according to timer setting Heating can be controlled on the user s device 1 Press ⓐ Power button to turn the power of temperature controller ON 2 Press ⓑ to enter heating control screen 4 Adjust ⓓ to left and right or press ⓔ button to select the wanted setting temperature a...

Page 37: ...lication ⓕ ⓐ ⓒ Hot water can be controlled on the user s device 1 Press ⓐ Power button to turn the power of temperature controller ON 3 Press ⓒ Hot water button to start hot water function 2 Press ⓑ to enter hot water control screen 4 Adjust ⓓ to left and right or press ⓔ button to select the wanted setting temperature and press ⓕ Confirm button ⓓ ⓔ ⓔ How to use hot water ⓑ ⓒ ⓒ ⓑ ⓑ ⓗ ⓖ ⓕ ⓔ ⓔ ⓔ Hot...

Page 38: ... 4 Press ⓕ OK button 5 After setting the timer press timer button on SMART CONTROL to operate the timer Refer to page for heating screen Reservation timer setting Heating timer can be set for different hours 24 hour timer setting ⓑ ⓐ ⓒ ⓐ ⓒ ⓕ Types of 24 hour timer include Standard 1 Standard 2 Weekend Personal 1 and Personal 2 Standard 1 Standard 2 and Weekend are basic modes New lifestyle pattern...

Page 39: ...smart phone 1 Press ⓐ Reservation button to change timer setting 4 Press ⓓ button to set cancel timer for the corresponding day 5 Chose the time wanted for heating in ⓔ 2 Press ⓑ Weekly timer button to select weekly timer 3 Press ⓒ Setting button to change timer Press ⓕ OK button once setting is done Reservation timer setting Heating timer can be set for different days of the week Weekly timer set...

Page 40: ...from actual conditions depending on the siuation and result in large battery consumption of the device Unnecessary boiler operation is reduced during outing and pleasant heating environment is provided by heating the house before returning 2 ⓑ can change distance between the house and user 2 4 6 8 and 10km 3 ⓒ can enable outing return notifications 1 Alarm can be turned ON and OFF by pressing butt...

Page 41: ...hot water is provided in the tiresome and busy morning ⓓ Setting can be repeated Additional functions 1 Press button ⓐ to set wake up time and day 2 Press button ⓑ to set volume of alarm and alarm sound 3 ⓒ can confiqure heating and hot water preheat functions for wake up mode ⓓ can change wake up time and day ⓓ ⓐ ⓒ ⓑ ⓒ ⓑ 07 ...

Page 42: ...m function ON OFF ⓕ can set volume of alarm sound ⓖ can set alarm sound ⓕ ⓖ ⓔ Current boiler status is displayed at the wanted time 1 Select the time you want to be ⓐ notified and press ⓑ OK button Additional functions ⓐ ⓑ ⓔ ⓔ ⓕ ⓕ ⓖ ⓖ On ...

Page 43: ...e alarm is a function that notifies changes in the setting of the boiler made by other users ⓑ Precaution alarm is a function that notifies precautions about times for inspection ⓒ Error alarm is a function that notifies occurrence of error in the boiler type of error and troubleshooting method Test 1 Test 2 ⓐ ⓑ T t Test Test Test Test Test Test Test Test Test Test Test Test Test est 1 1 1 1 1 1 1...

Page 44: ...ng the name of newdevice Additional functions 3 ⓒ The list an buttons allow to check the registered users and add delete users Up to 10 users can be added for each temperature controller 1 Press ⓐ button to change name of temperature controller 2 ⓑ When several Rinnai Wi Fi boilers are used select the boiler to change the setting Once selected Select is switched to Selected 4 Press ⓓ button to del...

Page 45: ...ide Change user information ⓓ ⓐ ⓑ ⓒ Change ⓐ User nickname Change ⓑ Password Enter ⓒ Current password and then enter new password Once input is done press ⓓ OK button Additional functions ⓓ ⓐ ⓒ ⓒ ⓑ ⓑ Gas Consumption ...

Page 46: ...rsion You can check the version of the application You can check the privacy of the application Press ⓐ Info Privacy button Press ⓐ Log out button to go back to the Log in page Additional functions ⓐ Info privacy ⓐ ...

Page 47: ...t of cold and hot water mixed 1 Configure hot water temperature as high 2 The amount of hot water is reduced when it is used in many places at the same time 3 Reduce the amount of cold water 1 Is air supply exhaust hole blocked 2 Is air supply or exhaust system disconnected or bent 1 Is the power cord connected 2 Is setting temperature lower than current temperature 3 Does 11 appear on the liquid ...

Page 48: ... water is continuously used for 1 hour or longer Clean the heating filter Refer to page 18 Check whether the intermediate gas valve is open Turn heating off and restart it Check whether gas supply pressure is normal Turn another gas device on Request inspection of the gas supplier Turn off with heating or hot water power button and restart If the same symptom recurs contact our service center for ...

Page 49: ...nomal flame detected Complete frost detected Exhaust closure Abnormal fan rotation 36 52 61 64 70 72 89 90 96 99 Turn heating off and turn it on again First apply for service by contacting our service center and switch heating method to floor heating Abnormal indoor temperature thermistor 35 Heating Heating Immediately call the technical support service of Rinnai Malfunction of thermistor return C...

Page 50: ...Installation ...

Page 51: ...Requirements for an Installation Location 1 Install a remote controller on the wall at the height of 1 2 1 5m from the floor Also the location provides a sufficient clearance for allowing of each access A living room or a main bed room could be suitable 2 Power Connection of the Remote Controller Power lines of the remote controller must be a two wire two layer vinyl chloride sheath copper wire an...

Page 52: ...f the remote controller it should be taken out in between the bottom of the bracket and the furrow on the remote controller 2 Mounting the Remote Controller to the Switch Box After separating the bracket from the remote controller and then affix the bracket with the flat headed screw comes with the boiler Connect the power line of the remote controller and then put the remote controller into the b...

Page 53: ...e adjustment Heating Hot water U E _ B 0 0 1 F W U E _ W 0 0 1 F W Wall mounted 120 H X 120 W X 16 6 D 229 Only thermostat 447 Total package DC 12V 3 5 Only thermostat 0 5 Only thermostat Power Consumption W Stand by Power W Heating water temperature 50 80 C indoor temperature 5 40 C 35 47 C adjusted by 1 C and above 50 C is adjusted to 50 55 and 60 C ...

Page 54: ...Memo ...

Page 55: ...Memo ...

Page 56: ...ver 161214 ...

Reviews: