Check that water is available at the heater before first
ignition.  (Turn the control to the “cold” position and push to
check water flow, then push the knob again to stop water
flow, then return it to a hot water position.

Fully open the gas valve on the unit.  Do not open any other
gas valve when the room’s gas valve is open.

TO TURN ON

: Push the control knob.  The burner will

ignite and hot water will flow.  Ignition can be checked in the
confirmation window.

TO TURN OFF

:Push the button again, and release.

Gas and water will stop automatically.

If the water trickles out a few seconds after the water is
turned off, it is not a fault.  Face the hot water outlet pipe
down so the water can flow out straight and the trickling will
lessen.

TEMPERATURE CONTROL

To increase the temperature of the water, turn the control
clockwise, to decrease it, anticlockwise.  (The water flow
will decrease as the temperature increases).

CAPACITY CHANGEOVER

When water temperature is high (in Summer etc.) turn the
capacity changeover level to “low”.  These will lessen gas
flow and lower water temperature.  When water
temperature is low (in Winter etc.) turn the lever to “high”.
This will increase gas flow and increase water
temperature.

COLD WATER ONLY

Turn the control to the “COLD” position, and push the but-
ton.  In this case, water flows without ignition.  If the control
knob is positioned in any other position, hot water will flow
out.  To stop the flow, push the button again.

BOILING WATER

Turn the control to “high” (Summer) or “high” (Winter).  Use
the “Summer” positioning when seasonal temperatures are
high and the “Winter” positioning when seasonal
temperature are low.
If there is too much steam, or over-boiling, turn the control
back slightly.
Turn the capacity changeover lever to “high”.
In the “high” positioning the following temperatures can be
reached:
“Summer”:

Water tempe=60°C

“Winter”:

Water tempe=80°C

LOW

HIGH

5

Summary of Contents for RUS-51FT

Page 1: ...hall be installed in accordance with Manufacturer s Instructions Local Gas Fitting Regulations Local Body Building Codes Installation Code for Gas Burning Equipment Any other relevant statutory regula...

Page 2: ...Changeover switch or the Control Water Temperature Knob Battery Changeover Indicator The Indicator informs of the necessity to change the battery before it goes flat One touch Operation The unit has...

Page 3: ...safe combustion prevention device to put the flame out Turn the appliance off Do not use this water heater in a bathroom Be particularly careful to provide sufficient ventilaton An open kerosene heate...

Page 4: ...ins CAUTION TO Avoid Burns After using the heater at the BOIL setting return the control to a lower temperature setting this will reduce the risk of burns to the next person Do not touch anything apar...

Page 5: ...iclockwise The water flow will decrease as the temperature increases CAPACITY CHANGEOVER When water temperature is high in Summer etc turn the capacity changeover level to low These will lessen gas fl...

Page 6: ...g hot water as spray may cause burns TO DRAIN THE HEATER if freezing conditions are expected 1 Turn the water and gas off at the control valves 2 Change the shower to the straight mode and bend the ou...

Page 7: ...around the unit Is there a smell of gas Is there a water leak in the unit or connecting parts BATTERY REPLACEMENT If the spark speed slows down replace the batteries as shown Batteries should last ove...

Page 8: ...ter is best installed at eye level provided the required clearances can be maintained Clearances shown must be maintained at all times 6 The wall must be strong enough to support the heater 10kg 7 Wat...

Page 9: ...as Check the unit is not too close to combustibles nothing obstructing daily use and maintenance that accessories have been installed correctly and that the unit is firmly attached When installation i...

Page 10: ...MJ h 42 0 NG 38 0 LPG CAPACITY TEMPERATURE 11 80 C rise VOLUME 1 6 4 51 min WATER VOLUME CONTROL Water Governor System MIN OPERATING WATER PRESSURE Min 35 kPa MAX OPERATING WATER PRESSURE 500 ELECTRI...

Page 11: ...ator lights up it will not light up or flash when the knob is turned to COLD or if instant ignition is difficult the batteries should be replaced Water flow is low and the flame fails during operation...

Page 12: ...er is flowing continuously the unit s flame will cut out after 15 20minutes The water will continue to flow Press the control knob to stop the water flow when you notice the flame has cut out WARNING...

Page 13: ...An overhaul by an appropriate serviceman is recommended if the unit gets extremely dirty 3 This unit is suitable for domestic use If it is used heavily eg In a cafe ensure frequent check ups for the...