THE FOLLOWING ARE NOT FAULTS

The unit makes a noise temporarily after ignition.  The unit ensures ignition a few seconds
after the user has pushed the knob.
Cannot ignite when the control knob is in the “COLD” position.  The unit is made not to ignite
cold water setting.

If the Unit has not been used for a prolonged period.

Clean all dirty parts and completely drain the unit of water.

Leave the water running for a little while before using.

Ignition may be difficult due to air in the gas pipes.  In this case the ignition must be
attempted until the air has been dispelled.

Take out the batteries (battery fluid leakage may cause damage to the unit).

AFTER SALES SERVICE

Before calling for service, go through the fault finding procedure on page 13.
Have the following details ready:

Model Name and Gas Type
Model number (on data plate or service code number)
The Problem
Person Details

SAFETY FEATURES

Prevention of Unit Being Left On

If hot water is flowing continuously, the unit’s flame will cut out after 15-20minutes.  The water
will continue to flow.  Press the control knob to stop the water flow when you notice the flame
has cut out.

WARNING

:  The air may be stale when you go to use the hot water heater again.  Please

change the air inside the room before using the unit again.

FLAME FAILURE DEVICE

If the burner’s flame has gone out due to wind etc., the gas will automatically cut out.  Press
the control knob to stop the water flow when you notice the flame has cut out.

WARNING

:  Wait 10 minutes before using the unit again, as there may be some gas still in

the unit.

Unsafe Combustion Prevention Device

The unsafe combustion prevention device will automatically turn off the appliance.  This is to
prevent the air quality due to lack of ventilation from reaching an unsafe level.  Press the
control knob to stop the water flow when you notice the flame has cut out and ventilate the
room.

WARNING

:  Ventilate the room before using the unit again.

If there is enough ventilation but the flame cuts out, the heat exchanger may be dirty.  Have the
unit checked by an appropriate serviceman.

13

Summary of Contents for RUS-51FT

Page 1: ...hall be installed in accordance with Manufacturer s Instructions Local Gas Fitting Regulations Local Body Building Codes Installation Code for Gas Burning Equipment Any other relevant statutory regula...

Page 2: ...Changeover switch or the Control Water Temperature Knob Battery Changeover Indicator The Indicator informs of the necessity to change the battery before it goes flat One touch Operation The unit has...

Page 3: ...safe combustion prevention device to put the flame out Turn the appliance off Do not use this water heater in a bathroom Be particularly careful to provide sufficient ventilaton An open kerosene heate...

Page 4: ...ins CAUTION TO Avoid Burns After using the heater at the BOIL setting return the control to a lower temperature setting this will reduce the risk of burns to the next person Do not touch anything apar...

Page 5: ...iclockwise The water flow will decrease as the temperature increases CAPACITY CHANGEOVER When water temperature is high in Summer etc turn the capacity changeover level to low These will lessen gas fl...

Page 6: ...g hot water as spray may cause burns TO DRAIN THE HEATER if freezing conditions are expected 1 Turn the water and gas off at the control valves 2 Change the shower to the straight mode and bend the ou...

Page 7: ...around the unit Is there a smell of gas Is there a water leak in the unit or connecting parts BATTERY REPLACEMENT If the spark speed slows down replace the batteries as shown Batteries should last ove...

Page 8: ...ter is best installed at eye level provided the required clearances can be maintained Clearances shown must be maintained at all times 6 The wall must be strong enough to support the heater 10kg 7 Wat...

Page 9: ...as Check the unit is not too close to combustibles nothing obstructing daily use and maintenance that accessories have been installed correctly and that the unit is firmly attached When installation i...

Page 10: ...MJ h 42 0 NG 38 0 LPG CAPACITY TEMPERATURE 11 80 C rise VOLUME 1 6 4 51 min WATER VOLUME CONTROL Water Governor System MIN OPERATING WATER PRESSURE Min 35 kPa MAX OPERATING WATER PRESSURE 500 ELECTRI...

Page 11: ...ator lights up it will not light up or flash when the knob is turned to COLD or if instant ignition is difficult the batteries should be replaced Water flow is low and the flame fails during operation...

Page 12: ...er is flowing continuously the unit s flame will cut out after 15 20minutes The water will continue to flow Press the control knob to stop the water flow when you notice the flame has cut out WARNING...

Page 13: ...An overhaul by an appropriate serviceman is recommended if the unit gets extremely dirty 3 This unit is suitable for domestic use If it is used heavily eg In a cafe ensure frequent check ups for the...

Reviews: