Linear installation guide 13563-H 08-19 |
13
Base board and connection cutouts
To ensure everything lines up and fits properly it’s recommended
that on the base the following dimensions are pencilled; glass
centreline, unit depth centreline, feet position, gas and room
thermistor cutouts.
Linear 800
Linear 1000
Linear 1500
A (room supply air)
50 mm
50 mm
255 mm
B (gas supply)
220 mm
220 mm
220 mm
C (support feet centres)
640 mm
740 mm
990 mm
D (support feet centres)
360 mm
460 mm
710 mm
E* (from front of cavity)
77 mm
77 mm
77 mm
* E asssumes 10 mm wall board
Additional framing notes
•
Wallboard is set 1 mm back from the front edge of the lips to allow for a slim edge plaster finish.
• To ensure the appliance performs correctly, without rattling, the Linear MUST BE installed on
a flat level support base. The joists must be capable of supporting a minimum of 1.5 times the
weight of the appliance—base panel is also designed to take the weight of the wallboard.
Issues caused by rattling fires not installed on a flat level base, as detailed in this guide,
will not be covered by warranty.
IMPORTANT
Framing dimensions
The framing dimensions have the studs offset. This is because the cavity needs to be
framed based on the centreline of the Linear glass, NOT the opening size
.
Where there is a requirement for a symmetrical installation, the cavity size will need to
increase. To calculate a rough opening width, double the flue to centreline figure on the
following pages.
IMPORTANT
E
A
B
Gas supply access
Thermistor / room supply air Ø 40 mm
Glass centreline
C
D