REU-VR2626WB (B26) /REU-VR2426WS (S26) /REU-VRM2626WG (INF26)
- 26 -
Issue 3 - 13/11/14 ©Rinnai
*Note 1 Fan Frequency rpm Conversion
(rpm) = (Hz) x15
*Note 2 Water Control Connections
*Note 3 Water Flow Servo Positioning
Display Monitor Contents
No.
Contents Units
Data
Range
01
Water flow sensor recognition flow
(Example 123 = 12.3L/min).
0.1L/min
0~400
02
Hot water Outlet thermistor temperature
(Example 20 = 20 C)
C
0~999
03
Hot water combustion time
(Example 6 = 600 hours)
100 hours
000~999
04
Hot water operation frequency
(Example 6 = 600 Operations)
100
0~999
05
Hot water fan frequency
Hz pulses/sec 0~999 *Note 1
06
water control connection
none
0 or 1 *Note 2
Bathroom water
Additional controller
Kitchen controller
“0”
“1”
Controls
connected
Display
No
“0”
Yes
“1”
07
Water flow servo present recognising
positioning
None
0~2 *Note 3
Servo Position
Open
Centre
Closed
Display “1”
“0”
“2”
08
Inlet water temperature
(PCB recognition value)
(Example 25 = 25 C)
C
0~999
09
Hot water fan current flow value
(Example 6 x 10 = 60 mA)
10 mA
0~999
10
Bath fill amount (this counts the litres
during bath fill operation).
Litres
0~999
11
Heat exchanger exit thermistor
temperature (Example 55 = 55 C)
C
0~999
12
Bypass servo present recognition positioning
(Example
0 = Closed
250 = Half open
500 = Open
Degrees
0~500