REU-VR2626WB (B26) /REU-VR2426WS (S26) /REU-VRM2626WG (INF26)
- 22 -
Issue 3 - 13/11/14 ©Rinnai
4. Solenoid Valve 1 (Small) (SV
1
)
Check Solenoid valve 1 if error indicator “11” is displayed.
a) Measure voltage between Brown-Black wires of main solenoid connector (
I
6
)
Normal:
11~13VDC
If normal, proceed to b.
Faulty:
Replace PCB.
b) Measure voltage between Solenoid 1 connectors.
Normal:
35~41
If normal, proceed to Solenoid Valve 2 (SV
2
) Circuit
Faulty:
Replace Solenoid 1
5. Solenoid Valve 2 (on Manifold)
a) Measure voltage between brown-black wires of solenoid valve 2 connector (
I
6
)
Normal:
11~13VDC
If normal, proceed to b.).
Faulty:
Replace PCB.
b) Measure resistance between Solenoid Valve 2 connectors.
Normal:
35~41
If normal, proceed to Solenoid Valve (
SV
2
) Circuit.
Faulty:
Replace Solenoid Valve 1.
6. Solenoid Valve 2 (Large) (SV
3
)
a) Measure voltage between black-yellow and black wires of solenoid valve 2 connector (
I
7
)
Normal:
11~13VDC
If normal, proceed to b.).
Faulty:
Replace PCB.
b) Measure resistance between Solenoid Valve 3 connectors.
Normal:
37~43
If normal, proceed to Modulating Valve Circuit.
Faulty:
Replace Solenoid Valve 2.
7. Modulating Solenoid Valve (POV)
a) Measure voltage between pink-pink wires of the modulating solenod valve.(
I
3
).
Normal:
2.0~15VDC
If normal, proceed to c.).
Faulty:
Replace PCB.
b) Measure resistance between modulating solenoid valve connectors.
Normal:
65~85
If normal, proceed to b.).
Faulty:
Replace PCB.
c) Check the gas burner pressure changes when set temperature on the water control changes from
37°C to 55°C.
Normal:
Burner gas pressure changes. Go to Water Flow Servo Circuit.
Faulty:
Burner gas pressure does not change. Replace Modulating Valve.