Flueing Installation Instructions
Rinnai Australia Pty Ltd 20/08/2003
Page 7 of 10
Multiple Vertical / Horizontal Installations
The terminal clearances in AS5601 / AG601 do not apply
to the Infinity REU-V2632FFU/REU-V2632FFUC Water
Heaters installed side by side.
The appliances are AGA certified to be installed side by
side as shown in
(Fig.8)
, allowing for a horizontal
distance of 160 mm between vertical flue terminals and
270 mm between horizontal terminals.
UP
UP
UP
FFCONDK
FFROOFCOWL
FFWPLATE
UP
UP
UP
UP
UP
UP
350
160
225
270
Minimum clearance 500
FFWALLTERM
Fig.8
Cutting the Flue Components
Note: the ONLY COMPONENTS that CAN be cut are:
FFPIPE1000, FFROOFCOWL
and
FFWALLTERM
1.
Using the dimensions shown on
page 9
, calculate
the required number and combination of extension
pieces and bends to be connected between the
Infinity unit and terminal, cut the appropriate
components to length as required.
2.
The outer plastic flue skin section of the wall
terminal and extension pieces should be cut to the
required length plus 35 mm, (the extra 35 mm
allows for the distance that the cut outer plastic flue
pipe section will penetrate into the socket of the
adjoining component). Likewise the inner metallic
flue section should be cut to the required length
plus 50 mm, (the extra 50 mm allows for the
distance that the cut inner flue penetrates into the
socket of the adjoining component).
3.
Ensure all ends are cut square (The use of a mitre
box will ensure a clean square cut).
4.
Ensure all cut ends are free from debris and burrs.
15
35
50
Required length
Penetration
Fig.9