Flueing Installation Instructions 

 

Rinnai Australia Pty Ltd     20/08/2003 

 

 

Page 7  of  10

  

 

Multiple Vertical / Horizontal Installations 

 
The terminal clearances in AS5601 / AG601 do not apply 
to the Infinity REU-V2632FFU/REU-V2632FFUC Water 
Heaters installed side by side.  
 
The appliances are AGA certified to be installed side by 
side as shown in 

(Fig.8)

, allowing for a horizontal 

distance of 160 mm between vertical flue terminals and 
270 mm between horizontal terminals. 
 
 
 

UP

UP

UP

FFCONDK

FFROOFCOWL

FFWPLATE

UP

UP

UP

UP

UP

UP

350

160

225

270

Minimum clearance 500

FFWALLTERM

 

 

Fig.8 

Cutting the Flue Components 

 
Note: the ONLY COMPONENTS that CAN be cut are: 

FFPIPE1000, FFROOFCOWL

 and 

FFWALLTERM

  

 

1. 

Using the dimensions shown on 

page 9

, calculate 

the required number and combination of extension 
pieces and bends to be connected between the 
Infinity unit and terminal, cut the appropriate 
components to length as required.  

2. 

The outer plastic flue skin section of the wall 
terminal and extension pieces should be cut to the 
required length plus 35 mm, (the extra 35 mm 
allows for the distance that the cut outer plastic flue 
pipe section will penetrate into the socket of the 
adjoining component). Likewise the inner metallic 
flue section should be cut to the required length 
plus 50 mm, (the extra 50 mm allows for the 
distance that the cut inner flue penetrates into the 
socket of the adjoining component). 

3. 

Ensure all ends are cut square (The use of a mitre 
box will ensure a clean square cut).

 

4. 

Ensure all cut ends are free from debris and burrs.

 

 
 

15

35

50

Required length

Penetration

 

 

Fig.9 

 
 
 

 

 

Summary of Contents for REU V2632FFU

Page 1: ...ly installed Water Heater Models REU V2632FFU REU V2632FFUC UP UP UP This Flue shall be installed in accordance with Manufacturer s Installation Instructions Local Gas Fitting Regulations Municipal Bu...

Page 2: ...el single skin or stainless steel coaxial flue If in doubt contact the Rinnai Australia Technical Advice Helpline 1300 366 388 2 Before commencing installation please read the Installation Instruction...

Page 3: ...rrs and file a slight bevel on the outer edge to reduce any damage to the seal when inserting into the connecting fitting See the section Cutting the Flue Components Fig 9 127mm Hole FFWALLTERM UP FFB...

Page 4: ...length of the horizontal terminal and cut to length allowing for the outer section of the flue to extend 10mm through the wall See the section cutting flue components Fig 9 6 From outside the building...

Page 5: ...e length can be up to 9 metres long and a maximum of 3 bends can be used 2 All vertical installations start with the vertical adaptor This MUST be connected with the larger end Black outer seal facing...

Page 6: ...the requirements of AS5601 AG601 Clause 5 13 6 2 Fig 5 3 5 If the total length of the flue exceeds 1 5 meters a condensate trap MUST be installed either vertically or horizontally adjacent to the heat...

Page 7: ...ing the dimensions shown on page 9 calculate the required number and combination of extension pieces and bends to be connected between the Infinity unit and terminal cut the appropriate components to...

Page 8: ...m the condensate trap connection point to the point of discharge or tundish outside the building There must be no tap valve or any other restrictions in the condensate drain and the tundish MUST NOT b...

Page 9: ...0 Tickness 1mm Tickness 2mm 25 25 5 85 163 136 UP 116 136 170 FFU Flue Part Numbers DESCRIPTION CODE NUMBER BAR CODE NUMBER Vertical Adaptor FFADAPT 9314109107692 Elbow 90 Degrees Bend Adaptor FFBEND9...

Page 10: ...any other opening into a building with the exception of sub floor ventilation Space heaters up to 50 MJ h input 150 Other appliances up to 50 MJ h input 500 Appliances over 50 MJ h input and up to 15...

Reviews: