Rinnai REU V2632FFU Installation Instruction Download Page 2

Flueing Installation Instructions 

 

Rinnai Australia Pty Ltd     20/08/2003 

 

 

Page 2  of  10

  

 

Contents:

 

 General...................................................................................................................2

 

 Important Installation Notes ...................................................................................2 
 Flueing Options ......................................................................................................3

 

 Installation Tips ......................................................................................................3

 

  Direct Flueing With Wall Terminal..........................................................................4

 

  Extended Horizontal Flueing With Wall Terminal ..................................................4

 

  Vertical Straight Flueing With Roof Terminal.........................................................5

 

  Combination Vertical / Horizontal Installations ......................................................6

 

  Multiple Vertical / Horizontal Installations ..............................................................7 

Cutting The Flue Components...............................................................................7

 

Condensate drain...................................................................................................8

 

Flue Dimensions & Part Numbers .........................................................................9

 

Minimum Flue Clearances .....................................................................................10

 

Contact Points........................................................................................................10 

 

Installation 

 
This flue must be installed by an authorised person, the Installation must conform to local 
regulations.  Installation must comply with the instructions supplied by Rinnai.

 

Service and removal must be carried out by an authorised person.

 

 

Approval

 

Approved by AGA as a suitable flueing system for Rinnai REU V2632FFU / REU V2632FFUC 
Gas Internal Water Heaters. 

 

General 
 

1.  These instructions only apply to Rinnai Infinity Flueing with white plastic outer pipe. These instructions do not 

apply to Rinnai Infinity Flueing with the stainless steel single skin or stainless steel coaxial flue. If in doubt 
contact the Rinnai Australia Technical Advice Helpline: 1300 366 388.  

2.  Before commencing installation, please read the 'Installation Instructions - General', located inside a pouch 

behind the front cover of all Infinity models. The Internal Infinity Range of water heaters must only be installed 
with Rinnai Infinity Fluing as referred to in these instructions. 

3.  The requirements of the current AS5601/AG601 and local authorities must be met, which is the installers 

responsibility. 

4.  The Required clearances of the Internal Rinnai Infinity when installed as a single unit are shown in Fig.1A The 

appliances are AGA certified to be installed side by side as shown on 

page 7

, allowing a Minimum distance 

between flues. 

 

270mm between horizontal terminals. 

 

160mm between vertical cowls. 

5.  The REU-V2632FFU/REU-V2632FFUC when correctly installed with the Rinnai approved flue components is a 

room-sealed appliance. No internal ventilation is required.  

6.  The fan assisted flue clearance dimensions in Fig 5 should be used, as the REU2632FFU is a fan-assisted 

appliance. 

7.  The outer plastic section of the coaxial flue complies with temperature hazard requirements and can be 

installed with zero clearance to combustible material.  

Summary of Contents for REU V2632FFU

Page 1: ...ly installed Water Heater Models REU V2632FFU REU V2632FFUC UP UP UP This Flue shall be installed in accordance with Manufacturer s Installation Instructions Local Gas Fitting Regulations Municipal Bu...

Page 2: ...el single skin or stainless steel coaxial flue If in doubt contact the Rinnai Australia Technical Advice Helpline 1300 366 388 2 Before commencing installation please read the Installation Instruction...

Page 3: ...rrs and file a slight bevel on the outer edge to reduce any damage to the seal when inserting into the connecting fitting See the section Cutting the Flue Components Fig 9 127mm Hole FFWALLTERM UP FFB...

Page 4: ...length of the horizontal terminal and cut to length allowing for the outer section of the flue to extend 10mm through the wall See the section cutting flue components Fig 9 6 From outside the building...

Page 5: ...e length can be up to 9 metres long and a maximum of 3 bends can be used 2 All vertical installations start with the vertical adaptor This MUST be connected with the larger end Black outer seal facing...

Page 6: ...the requirements of AS5601 AG601 Clause 5 13 6 2 Fig 5 3 5 If the total length of the flue exceeds 1 5 meters a condensate trap MUST be installed either vertically or horizontally adjacent to the heat...

Page 7: ...ing the dimensions shown on page 9 calculate the required number and combination of extension pieces and bends to be connected between the Infinity unit and terminal cut the appropriate components to...

Page 8: ...m the condensate trap connection point to the point of discharge or tundish outside the building There must be no tap valve or any other restrictions in the condensate drain and the tundish MUST NOT b...

Page 9: ...0 Tickness 1mm Tickness 2mm 25 25 5 85 163 136 UP 116 136 170 FFU Flue Part Numbers DESCRIPTION CODE NUMBER BAR CODE NUMBER Vertical Adaptor FFADAPT 9314109107692 Elbow 90 Degrees Bend Adaptor FFBEND9...

Page 10: ...any other opening into a building with the exception of sub floor ventilation Space heaters up to 50 MJ h input 150 Other appliances up to 50 MJ h input 500 Appliances over 50 MJ h input and up to 15...

Reviews: