30
TECHNICAL DETAILS
Infinity Model
Continuum 11i
Continuum 11i-fp
Continuum 14i
Continuum 14i-fp
Unit
Installation
Internal
Burner Operating Gas Pressures
See page 27
Flue System
Room Sealed Forced Draught
Temp. Range
35,37
-
48,50,55,60
°C
Ignition
Direct electronic ignition
Gas Consumption & Capacities
minimum
conditions
H
i
= net calorific value H
s
= gross calorific value
G20 Nat Gas: Input Q
m:
Hi/Hs | Useful output P
m
6.10 / 6.80 | 5.60
kW
G20 Nat Gas flow V
m
0.65
m
3
/hr
G230 Air Propane: Input Q
m:
Hi/Hs | Useful output P
m
6.10 / 6.60 | 5.60
kW
G230 Air Propane flow V
m
0.50
m
3
/hr
G30 Input Q
m
: Hi/Hs | Useful output P
m
6.70 / 7.26 | 5.80
kW
G30 flow V
m
0.21
m
3
/hr
G31 Input Q
m
: Hi/Hs | Useful output P
m
5.90 / 6.40 | 5.10
kW
G31 flow V
m
0.24
m
3
/hr
Gas Consumption & Capacities
nominal
conditions
H
i
= net calorific value H
s
= gross calorific value
G20 Nat Gas: Input Q
n
: Hi/Hs | Useful output P
n
21.60 / 24.0 | 19.20
kW
G20 Nat Gas flow V
n
2.30
m
3
/hr
G230 Air Propane: Input Q
n
: Hi/Hs | Useful output P
n
21.60 / 23.50 | 19.20
kW
G230 Air Propane flow V
n
1.77
m
3
/hr
G30 Input Q
n
: Hi/Hs | Useful output P
n
24.70 / 26.77 | 21.50
kW
G30 flow V
n
0.77
m
3
/hr
G31 Input Q
n
: Hi/Hs | Useful output P
n
21.60 / 23.50 | 18.80
kW
G31 flow M
n
0.88
m
3
/hr
Country of destination
GB/IE
Gas category and pressure
I
2H
G20
-
20mbar / I
3P
G31
-
37mbar
Type
C13 / C33 Indoor
Max Flow ( Cold water temperature 5°C / 25°C )
5.75 / 8.6
L/min
Min Operation Flow
2.4
*
L/min
Water Pressure (p
w
)
0.7
*
-
10.00 (recommended 2.0 min)
bar
Power Supply
230 V / 50 Hz
Electric Consumption (normal / stand
-
by / anti
-
frost**)
50 / 8 / 60
**
68 / 6 / 71
**
W
Ignition safety time T
SAmax
4.5
Sec.
Protection Factor
IPX4
Weight
16
16
kg
NOx at Max Input GCV O2 0% G20 / G30 / G31
145 / 185 /
-
mg/kWh
Load Profile
S
Water Heating Efficiency η wh
60.6
%
Daily Fuel Consumption Qfuel
3.214
kWh
Daily Electrical Consumption Qelec
0.200
kWh
Sound Power Level L WA
56
dB
All input and output values and flows are given at 15°C and 1013,25 mBar.
* Minimum operation flow based on temperature setpoint and inlet conditions.
** Only on models: Continuum 11i-fp and Continuum 14i-fp.
Summary of Contents for REU-1110FFU(F)-E
Page 8: ...8 OPERATION...
Page 17: ...17 MAIN COMPONENTS...
Page 29: ...29 DIMENSIONS...
Page 32: ...32 FLOW CHART...
Page 33: ...33 WIRING DIAGRAM REU 1110FFU E REU 1110FFU F E...
Page 35: ...35 WATER FLOW CHARACTERISTICS REU 1110FFU E REU 1110FFU F E...
Page 36: ...36 LETTER OF COMPLIANCE...
Page 37: ...37 CE CERTIFICATE...
Page 39: ...39 COMMISSIONING CHECK LIST COMMISSIONING SHEET...
Page 40: ...40 SERVICE RECORD...