24
FLUE REQUIREMENTS
BS5440—1 : 2008
Symbol
Terminal Position
Dimen-
sion
A
Directly below an opening, air brick, opening windows, ect.
300mm
B
Above an opening, air brick, opening window, ect.
300mm
C
Horizontaly to an opening, air brick, opening window, ect.
300mm
D
Below plastic gutters, soil pipes, drain pipes, ect.
75mm
E
Below eaves
200mm
F
Below balconies or car port roof
200mm
G
From vertical drain pipe or soil pipe
150mm
H
From and internal or external corner
300mm
I
Above ground, roof or balcony level
300mm
J
From surface facing the terminal
600mm
K
From terminal facing terminal
1200mm
L
From opening in the car port (eg door, window ect) into the dwell-
1200mm
M
Vertically from terminal on the same wall
1500mm
N
Horizontally from terminal on the same wall
300mm
O
From the wall on which the terminal is mounted
0
P
From a vertical structure on the roof
N/A
Q
Above intersection with the roof
300mm