Rinnai 28
RDV 600_700ER IM
Step 5. Checking Supply Pressure (Ensure gas is connected)
1. Remove the gas inlet test point screw
(4)
, and connect the positive pressure manometer hose. Refer to valve
drawing above.
2. Press the heater ON/OFF button
(12)
, on the PCB control panel to start the ignition sequence. The appliance
will ignite normally. Refer to PCB Control panel image below.
Natural Gas
Propane Gas
Minimum Supply pressure
1.13 kPa
2.50 kPa
Maximum Supply pressure
3.50 kPa
3.00 kPa
Refer to chart for the correct gas settings, (data plate values override values printed in this instruction).
3. Check the pressures as per the chart below for the correct gas type. Ensure all other gas appliances in the
household are running on 'High'
4. Press the heater ON/OFF button
(12)
to stop the appliance operation.
5. Disconnect the manometer hose and replace the inlet test point screw
(4)
. Check for leaks using soapy water
solution.
Step 6. Checking and Setting burner gas pressure
1. Remove the main burner test point screw
(1)
, and connect the positive pressure manometer hose.
2. Press the heater ON/OFF button
(12)
, on the PCB control panel to start the ignition sequence. The appliance
will ignite normally. Refer to PCB Control panel image above.
3. Press the 'TEST' button
(6)
, twice on the PCB control panel, the igniter will spark and the appliance will light
to its lowest setting, (Main burner - stage 1), and the display
(12)
, will show
PL
(stage 1).
4. Press the 'UP' button
(8)
or 'DOWN' button
(9)
to adjust to the required value if values are different to those
in the table below.
Natural Gas
Propane Gas
Model
RDV600ER
RDV700ER
RDV600ER
RDV700ER
PL
(stage 1)
0.20 kPa
0.20 kPa
0.50 kPa
0.50 kPa
P
(stage 7)
0.90 kPa
0.86 kPa
1.95 kPa
1.92 kPa
Refer to chart for the correct gas settings, (data plate values override values printed in this instruction).
4
1
2
3
5
6
8 13
12
7
11
9
10
COMMISSIONING