background image

R98LSe (VA3237W)  

Type of Appliance 

Rinnai model number 

Operation / Installation 

Minimum/Maximum Gas Rate (Input) 

Electrical 

 
Electrical Consumption 

 
 
Ignition System 

Hot Water Capacity 

Temperature 

 
Temperature (without remote)  

Approved Gas Types 

Thermal Efficiency 

Service Connections 

 
 
Water Flow Control 

Minimum/Maximum Water Supply Pressure 

Temperature controlled, continuous flow, gas hot water system 

REU-VA3237W 

Forced combustion; outdoor only 

19,000 - 237,000 BTU/h (Natural Gas or Propane) 

Appliance: 

 

 

AC 120 Volts - 60 Hz 

Controller: 

  DC 

12 

Volts 

Normal 

   99 

watts 

Standby   2 

watts 

Anti-frost protection 

 

116 watts 

Direct electronic ignition 

0.6 to 7.9 GPM (50° F rise) 

0.9 to 9.8 GPM (35° F rise) 

98° - 140° F  (98° - 185° F available with the MCC-91 controller for 
commercial and hydronic applications) 

120° F (factory default) 

Natural or Propane (ensure unit matches gas type) 

Natural Gas: 83% 

 

Propane: 83% 

Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 

Water flow sensor, electronic water control and by-pass control  

15 - 150 PSI (50 PSI or above is recommended for maximum flow) 

© 2008 Rinnai Corporation 

R98LSe SP                            5/2008 

FLOW TABLE 

Water Flow Capacity Curve 

 