Vent system and air intake must be installed
according to the installation instructions.
There is a negative pressure on vent system (Pressure
difference). Check to see if fan motor is spinning.
The E29 is triggered immediately after fan check code 5 during the starting sequence. If during fan
check 5 the fan remains spinning more than 150 rpms an E29 will occur.
Causes:
-
Wind driving into a concentric terminal. Replace with 90 degree terminal or for best results
use a roof terminal.
-
Venting running a long distance in a cold attic space causing a thermo syphon after fan check.
Use room air for combustion if conforming to NFPA 111 guidelines for room air or use
concentric terminal directly through the roof.
Summary of Contents for Q series
Page 4: ...4 008082013GW ...
Page 5: ...5 008082013GW Parts of the Boiler ...
Page 15: ...15 008082013GW Flue sensor or thermostat contact open ...
Page 27: ...27 008082013GW ...
Page 34: ...34 008082013GW Replace MCBA board main board ...
Page 39: ...39 008082013GW T1 Sensor Contact for supply sensor T1 open indicated by infinite ohm reading ...
Page 41: ...41 008082013GW ...
Page 42: ...42 008082013GW ...
Page 43: ...43 008082013GW Electrical short circuit possible water damage to MCBA main board ...
Page 47: ...47 008082013GW E 115 Replace MCBA board ...
Page 49: ...49 008082013GW Additional Troubleshooting Instructions ...
Page 50: ...50 008082013GW ...
Page 51: ...51 008082013GW Checking the O2 Setting ...
Page 55: ...55 008082013GW ...
Page 57: ...57 008082013GW Altering adjustments ...
Page 59: ...59 008082013GW ...
Page 60: ...60 008082013GW Activating factory settings Green button function ...
Page 61: ...61 008082013GW Isolating the boiler ...
Page 62: ...62 008082013GW Reset service interval counter ...