N-BW2 Networker Bridge (WIFI)
API-N-BW2
Issue 1.3 Page 20 of 48
GROUP2
COMMAND
Values
Description
{“ZUS”: {
---
---
Common Zone Status
“MT”: “###”
R
000 – 999
Measured temperature (x10). (999 indicates undefined)
“AE”: “$”
R
(Y/N)
Auto enabled (Calling for heat)
Y
= Yes
N
= No
{“ZAS”: {
---
---
Zone A Status
“MT”: “###”
R
000 – 999
Measured temperature (x10). (999 indicates undefined)
“AE”: “$”
R
(Y/N)
Auto enabled (Calling for heat)
Y
= Yes
N
= No
{“ZBS”: {
---
---
Zone B Status
“MT”: “###”
R
000 – 999
Measured temperature (x10). (999 indicates undefined)
“AE”: “$”
R
(Y/N)
Auto enabled (Calling for heat)
Y
= Yes
N
= No
{“ZCS”: {
---
---
Zone C Status
“MT”: “###”
R
000 – 999
Measured temperature (x10). (999 indicates undefined)
“AE”: “$”
R
(Y/N)
Auto enabled (Calling for heat)
Y
= Yes
N
= No
{“ZDS”: {
---
---
Zone D Status
“MT”: “###”
R
000 – 999
Measured temperature (x10). (999 indicates undefined)
“AE”: “$”
R
(Y/N)
Auto enabled (Calling for heat)
Y
= Yes
N
= No
{“APS”: {
---
---
System Schedule Setup
“AV”: “$”
W
Y/N
Active
Y
= Yes
N
= No
“DY”: “$$$”
W
MON-SUN
Day of the week to program (Individual day grouping)
(MON. TUE, WED, THU, FRI, SAT, SUN)
“WD”: “$”
W
Y/N
Program weekdays (Weekday day grouping)
Y
= Yes
N
= No
“TP”: “$”
W
W,L,R,P,S
Time period being programmed
W
L
R
P
S
Wake
Leave
Return
Pre-Sleep
Sleep
“TM”:
“hh:mm”
W
00-23:00-59
Time period start time in 24 hour format
“SP”: “##”
W
00 – 30
Time period set point temperature (< 8 = OFF)
“ZA”: “$”
W
N/F
Zone A programmed state
F
= OFF
N
= ON
“ZB”: “$”
W
N/F
Zone B programmed state
F
= OFF
N
= ON
“ZC”: “$”
W
N/F
Zone C programmed state
F
= OFF
N
= ON
“ZD”: “$”
W
N/F
Zone D programmed state
F
= OFF
N
= ON
TABLE 4.3.1a: Networker System {“HGOM”: Group
Single Set Point Operation