background image

  

10 

 

 |   

Continuous Flow Water Heater Operation Guide 04-12

Universal controller (Compact)

Turning on
If the water controller is switched 
off (no digits displayed in the 
digital window) press the On/Off 
button once. The On indicator 
will illuminate, indicating the 
continuous flow water heater will 
be ready to supply hot water once 
a hot water tap is opened.

Adjusting the temperature
Select the desired temperature 
using the ‘Hot water temp.’ up and 
down buttons until the required 
temperature is displayed.

To operate the continuous flow 
water heater, open any hot water 
tap. This will automatically light the 
burner providing hot water. The 
water heater ‘In Use’ indicator will 
illuminate on the water controller.

Once the hot water is running, 
if the set temperature is either 
too hot or cold, press the ‘Hot 
water temp.’ up or down buttons 

until the desired temperature is 
reached.

Muting the ‘beep’ sound
The ‘beep’ sound can be muted by 
pressing the ‘Hot water temp.’ up 
and down buttons simultaneously 
for more than three seconds.

How to use two or more 
Compact controllers
Turning on
If the controllers are switched off, 
press the On/Off button once. 
The On indicator on the desired 
controller will illuminate, indicating 
that the hot water unit will be 
ready to supply hot water once a 
hot water tap is opened.

Transferring priority
An illuminated On/Off indicator 
confirms that the desired 
controller is in control of the water 
delivery temperature. If the On/
Off indicator is not illuminated 
press the ‘Transfer’ button once 

(while water is not flowing). The 
On/Off indicator on the controller 
will illuminate indicating that the 
hot water temperature control has 
been transferred to this controller 
and that the continuous flow water 
heater will be ready to supply hot 
water.

Adjusting the temperature
Select the desired temperature 
using the ‘Hot water temp.’ up and 
down buttons until the desired 
temperature is displayed.

Once the hot water is running, if 
the set temperature is too hot or 
cold, press the ‘Hot water temp.’ 
up and down until the desired 
temperature is reached.

With the water running the 
temperature can be adjusted down 
as desired, but as a safety feature, 
can only be adjusted up as far as 
43 °C. To increase the temperature 
above 43 °C, first stop the water 
flow.

WATER HEATER

'In Use' INDICATOR

DIGITAL MONITOR

TEMPERATURE

CONTROL BUTTONS

CONTROLLER
ON INDICATOR

TRANSFER BUTTON

ON/OFF BUTTON

Indicates that a water 
heater is in operation and 
delivering hot water.

Indicates the temperautre
selected. Error message will
flash in event of fault.

Used to select water temperature.

Indicates if this temperature
controller is in control of 
water delivery temperature.

Used to transfer control priority
between the controllers. 
The controller with
priority has command of the
hot water delivery temperature.

Used to switch the water 
heater on and off.

HOT WATER

Summary of Contents for Infinity EF24

Page 1: ...Continuous flow water heaters Operation guide For Rinnai continuous flow water heaters manufactured from 2010 onwards serial number 09 12 xxxxxx...

Page 2: ...ing must be carried out by an authorised person being in New Zealand a licensed gasfitter Owner please retain this manual for future reference Installer please leave this manual with the owner Warning...

Page 3: ...General information 7 General controller information 8 Universal controller Compact 10 Kitchen Deluxe controller 11 Bathroom Deluxe controller 12 Troubleshooting 15 Service record 17 Draining your wat...

Page 4: ...without draining the water heater Instructions for draining the water heater can be found at the back of this guide Principle of operation If no controllers are fitted the opening of any hot water tap...

Page 5: ...New Zealand can severely burn a child in less than half a second At 55 C preset temperature for domestic Rinnai continuous flow water heaters it takes half a minute Always Test the water temperature...

Page 6: ...ration Guide 04 12 General safety Keep flammable materials spray cans fuel containers pool chemicals trees shrubs etc well clear of the flue outlet Do not Touch the unit cover or the flue outlet Inser...

Page 7: ...vice centre in your area For reliable operation Rinnai continuous flow water heaters in domestic applications should be serviced every three years including inspection of the flue system if installed...

Page 8: ...ollers off after use As a safety precaution if a kitchen controller temperature is set above 50 C transferring and then returning priority will result in a default set temperature of 50 C This is a sa...

Page 9: ...on for delivery of hot water The water heater will not heat water unless the controller s are turned on If water is flowing before a controller is turned on the water heater will not heat the water T...

Page 10: ...minated On Off indicator confirms that the desired controller is in control of the water delivery temperature If the On Off indicator is not illuminated press the Transfer button once while water is n...

Page 11: ...the digital monitor the word Clock will be displayed and the clock digits will flash if this is the first time the clock has been set the starting time will be AM 12 00 Use the up and down buttons to...

Page 12: ...lected Shower Saver Bath Fill volume decreasing while the shower runs or the bath fills In the event of a fault error message codes will flash here In normal Shower Saver Bath Fill modes these buttons...

Page 13: ...period When filling a bath for the first time it is recommended that a low bath fill volume such as 60 litres or lower be used During subsequent bath fills the volume can then be adjusted to suit your...

Page 14: ...will flash 4 A tone will sound 5 The voice prompt will say Bath fill is complete Turn off the bath hot water tap and push the Bath Fill button Follow the voice prompt instructions Note the water heat...

Page 15: ...checking sensor wiring for damage measuring resistance of sensor checking combustion fan checking internal flue leakage checking flue system integrity and possibly replacing sensor 52 Gas modulating v...

Page 16: ...ill on Check gas isolation valve at the unit and gas meter are fully open Open your hot water tap fully Unit starts then water goes cold Check power is still on Open hot water tap fully Excessive temp...

Page 17: ...tact Comments Service 3 Date Company Address Phone Contact Comments Service 4 Date Company Address Phone Contact Comments Service 5 Date Company Address Phone Contact Comments Service 6 Date Company A...

Page 18: ...Flow Water Heater Operation Guide 04 12 Service record parts replaced Unit Run Hours Ignition Cycles Part Replaced Reason Date Company All parts must be replaced with genuine replacement parts availab...

Page 19: ...een recent hot water use 1 Turn off any water controllers in the building and then turn off the water gas and power at the unit 2 To flush the water heater open all hot water taps in the building Refe...

Page 20: ...h a continuous flow unit Water plug Water filter Condensate trap drain plug Hot water outlet Hot water drain plug Cold water inlet drain Condensate trap and water drain plugs EF models only Wash hands...

Page 21: ...n Guide 04 12 21 Installer details Company name Installer name Address Phone Mobile Certificate of compliance number for installation Signed Date Installer please remember to complete and leave the co...

Page 22: ...innai controller 12 years pro rata 3 years 5 years 3 years Commercial 5000 hours or 3 years 1500 hours or 1 year 1500 hours or 1 year 1500 hours or 1 year Whichever comes first Domestic vs commercial...

Page 23: ...ation Guide 04 12 23 Please keep these details in a safe place for future reference ATTACH YOUR PROOF OF PURCHASE HERE RECORD YOUR DETAILS OF PURCHASE BELOW Retailer Retailer address Date of purchase...

Page 24: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz U278 2778 01 060 00012 31314 7...

Reviews: