49
Model
REU-A1720W-E
Unit
Installation
Outdoor
G20 Nat Gas min gas pression
1.58
mbar
G20 Nat Gas max gas pression
9.00
mbar
G230 Air/Propane min gas pression
1.89
mbar
G230 Air/Propane max gas pression
11.57
mbar
G30 Butane min gas pression
2.29
mbar
G30 Butane max gas pression
11.60
mbar
G31 Propane min gas pression
2.29
mbar
G31 Propane max gas pression
15.10
mbar
Flue system
Forced flue, direct
-
Temperature range with water controller
37-46, 48, 50, 55, 60, 65
°C
Tempearature range with push buttons
40, 42, 50, 55, 60, 65
°C
Ignition
Direct electronic ignition
-
Gas consumption & capacities min operation
(Hi = net calorific value - Hs = gross calorific value)
G20 Nat Gas: Input Qm: Hi/Hs | Output Pm
4.10/4.53 | 3.56
kW
G20 Nat Gas flow normal operating conditions Vm
0.43
m
3
/h
G230 Air/Propane Input Qm: Hi/Hs | Output Pm
4.10/4.53 | 3.56
kW
G230 Air/Propane flow normal operating conditions Vm
0.35
m
3
/h
G30 Input Qm: Hi/Hs | Output Pm
4.10/4.53 | 3.56
kW
G30 flow normal operating conditions Mm
0.33
kg/h
G31 Input Qm: Hi/Hs | Output Pm
4.10/4.53 | 3.56
kW
G31 flow normal operating conditions Mm
0.33
kg/h
Gas consumption & capacities nominal operation
(Hi = net calorific value - Hs = gross calorific value)
G20 Nat Gas: Input Qn: Hi/Hs | Output Pn
32.40/36.00 | 28.40
kW
G20 Nat Gas flow ref. conditions Vr
3.43
m
3
/h
G230 Air/Propane: Input Qn: Hi/Hs | Output Pn
33.10/36.00 | 28.40
kW
G230 Air/Propane flow ref. conditions Vr
2.72
m
3
/h
G30 Input Qn: Hi/Hs | Output Pn
33.20/36.00 | 28.40
kW
G30 flow normal operating conditions Mn
2.63
kg/h
G31 Input Qn: Hi/Hs | Output Pn
33.10/36.00 | 28.40
kW
G31 flow normal operating conditions Mn
2.58
kg/h
Country of destination
Refer to dataplate
-
Gas category and pressure
II2H3P, II2H3B/P, II2HM3B/P
G20-20mbar, G230-20mbar,
G31-37mbar, G30-30mbar
-
Type
A3
-
Max water flowrate
20
l/min
Min operation flowrate
ON=2 / OFF=
1
l/min
Min operating water pressure (Pmin)
0.10
bar
Water pressure (@nom/max flowrate - max) - (Pw)
1.00/1.40 - 8.30
bar
Power supply
230V/50Hz
-
Electric consumption (remote/standby/antifrost)
80/1.5/116
W
Noise level
56
dB (A)
Ignition safety time TSAmax
4.2
sec.
Weight
14.5
kg
IP protection
IPx5D
-
Anti-freeze temperature protection
-20
2
°C
NOx
50
mg/kWh
1
minimum water flowrate may vary depending on the temperature setting and the inlet water temperature.
2
when protected from direct wind exposure
Summary of Contents for Infinity 14e
Page 6: ......
Page 18: ......
Page 22: ...22 2 3 1 INDOOR MODELS...
Page 34: ......
Page 39: ...39 3 5 FLOW CHART...
Page 51: ......