40
3.6 WIRING DIAGRAM AND DIAGNOSTIC POINTS
COMPONENT
MEASUREMENT POINT
RANGE OF VALUE
CN/Con.re
WIRE COLOUR
MAIN POWER CODE
B
BR-BL
AC198-264V
REMOTE CONTROLLER
A1
BK-BK
DC11-13V
IGNITER
D3
R-BK
DC11-13V (DURING IGNITION)
FLAME ROD
D10
Y-BODY (GND)
OVER DC5V (DURING OPERATION)
Y-FlAME ROD
OVER 1μA (DURING OPERATION)
THERMAL FUSE
D7
R-R
BElOW DC1V,BElOW 1Ω
OVERHEAT SWITCH
D2
R-R
BElOW DC1V,BElOW 1Ω
MODULATING SOLENOID VALVE
D9
GY-GY
DC2-17V / 10-20Ω
MAIN SOLENOID VALVE
R-BK
DC8-13.5V / 15-25Ω
SOLENOID VALVE 1
D8
BL-BK
DC8-13.5V /20-30Ω
SOLENOID VALVE 2
Y-Bk
OUTGOING WATER TH1
D5
W-W (No. 1 , 2)
15°C : 11.4-14.0kΩ
30°C : 6.4-7.8kΩ
45°C : 3.6-4.5kΩ
60°C : 2.2-2.7kΩ
100°C : 0.6-0.8kΩ
OUTGOING WATER TH2
W-W (No. 3, 4)
HEAT EXCHANGER OUTGOING WATER TH
D11
W-W
FREEZE PROTECTION THERMISTOR
D6
Y-Y
0°C : 38-43kΩ
10°C : 22-26kΩ
20°C : 14-17kΩ
WATER FLOW SENSOR
D4
R-Bk (GND)
DC11-13V
Y-Bk (GND)
DC4-7V (PUlS. 6-200HZ)
WATER FLOW CONTROL DEVIC
F1
R-OR,P-OR
DC5-8V (DURING OPERATION)
BL-OR,W-OR
R-P,BL-W
40-60Ω
BR-GY
BELOW DC1V(FULL OPEN, FULL COLSE LIMITER ON)
DC4-6V(LIMITER OFF)
COMBUSTION FAN
D1
R-Bk (GND)
DC7-48V
Y-Bk (GND)
DC11-14V
W-Bk (GND)
DC2-14V (PUlS. OVER 20HZ=300RPM)
Summary of Contents for Infinity 14e
Page 6: ......
Page 18: ......
Page 22: ...22 2 3 1 INDOOR MODELS...
Page 34: ......
Page 39: ...39 3 5 FLOW CHART...
Page 51: ......