Rinnai 

Split AC IM

OPERATION
DO NOT

 let the air conditioner run for extended periods when the humidity is very high or when 

doors or windows are left open. As this may result in an excessive operational loading and lead 

to product failure.

DO NOT 

cover or place articles on any part of this appliance.

DO NOT 

touch, operate or clean the air conditioner with wet hands. It may result in electric 

shock or product failure.

DO NOT 

insert hands or other objects through the air inlet or outlet while the appliance is 

operating. It may result in electric shock or product failure.

DO NOT 

place a heater or other heating appliances near this appliance, always ensure sufficient 

ventilation when using this appliance and a heating appliance at the same time. Failure to do so 

may result in product mis-operation.

Turn main power off before cleaning. Failure to do so may result in fire, electric shock, or product 

failure.

DO NOT 

use solvents, abrasives or harsh detergent to clean any part or surface of this appliance 

or spray water or allow liquids to enter the indoor unit. The enclosure of the appliance and remote 

control can be cleaned using a soft, damp cloth and a mild detergent.

NEVER

 touch the metal parts of the air conditioner when you remove the air filter. It may result 

in electric shock or product failure.

DO NOT 

leave flammable materials near the appliance. It may result in explosion or fire.

If there is excessive noise, smell or smoke coming from the appliance, turn the appliance off, 

isolate the power supply and contact a service agent. 

DO NOT

 operate the appliance if it has been submerged into water due to flooding, contact a 

service agent. Failure to do so may result in electric shock, fire, serious injury, or product failure.

This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their 

safety.
Children should be supervised to ensure that they 

DO NOT

 play with the appliance.

The air conditioning system is designed to achieve consumer comfort. It is 

NOT 

designed 

for commercial applications requiring a controlled atmosphere (i.e. computer rooms, food 

preservation, etc.)

DO NOT 

block the inlet or outlet of air flow. It may result product in failure.

DO NOT 

drink the condensate water drained from the appliance. This condensate is not potable 

and may present a health risk if consumed.

DO NOT 

expose people, animals or plants directly to the cold or hot discharge of the appliance. 

It may result in serious injury.

DO NOT 

mix the batteries for the remote control with other types of batteries or mix new batteries 

with used batteries. Failure to do so may result in product failure. 

STOP 

using the remote control 

if there is a battery fluid leak

.

OPERATION RANGE LIMITATIONS

The table below indicates the temperature ranges the air conditioner can be operated within.

MODE

Cool Mode

Heat Mode

Dry Mode

Room Temperature

> 17°C

< 27°C

> 17°C

Outdoor Temperature

-15°C ~ 52°C

-15°C ~ 24°C

-15°C ~ 52°C

WARNING

WARNINGS AND IMPORTANT INFORMATION

Summary of Contents for HINRJ25B

Page 1: ...SNRJ70B HSNRJ80B Indoor HINRJ25B HINRJ35B HINRJ50B HINRJ70B HINRJ80B Outdoor HONRJ25B HONRJ35B HONRJ50B HONRJ70B HONRJ80B REFRIGERANT R32 J Series Split Type Wall Mounted Air Conditioner Installation Manual TURBO C LRSWING COOL SWING SPEED RUN ...

Page 2: ...ons Current AS NZS 3000 AS NZS 5141 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed only by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer s instructions ...

Page 3: ... Indoor Unit 9 Wall Mounting Plate 9 Wall Penetration 9 Drain Pipe 9 Electrical Connections 10 Wall Installation 10 Outdoor Unit 11 Electrical Connections 11 DRED Connection optional 12 Condensate Drain Installation 12 Refrigerant Pipes 13 Flaring 13 Connecting Vapour Liquid Pipes To Indoor Outdoor Units 13 Air Purging Leakage Test 14 Evacuation Vacuum Method Leak Test 14 Adding Refrigerant for Lo...

Page 4: ... or unpacking this appliance Failure to do so may result in serious injury or product failure DO NOT modify the electrical wiring of this appliance If the control power wiring is damaged or deteriorated then it must be replaced by an authorised person Failure to do so may result in electric shock fire serious injury or product failure DO NOT install the air conditioner on an unstable or non level ...

Page 5: ...formance Install the drain hose properly for smooth drainage of condensed water Make sure to check for and rectify any refrigerant leaks after you install or repair the unit This appliance uses R32 difluoromethane refrigerant which is a flammable gas class 2 2 according to AS NZS 1677 and must be handled by a refrigeration mechanic with appropriate Australian refrigerant handling licence WARNING R...

Page 6: ...he appliance off isolate the power supply and contact a service agent DO NOT operate the appliance if it has been submerged into water due to flooding contact a service agent Failure to do so may result in electric shock fire serious injury or product failure This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experie...

Page 7: ...ccess panel 7 Refrigerant pipes electrical cable s covered with binding tape 8 Condensate drain hose covered with binding tape 9 Refrigerant entry for service and installer use only 10 Outdoor unit air inlet on rear left side of unit 11 Outdoor unit air discharge and protective grille on front of unit WEIGHTS DIMENSIONS Model HSNRJ25B HSNRJ35B HSNRJ50B HSNRJ70B HSNRJ80B Weight kg Indoor 9 5 12 0 1...

Page 8: ...outdoor unit is located so it can be accessed for service and replacement Do not place animals and plants near the air discharge The clearances shown MUST BE maintained PIPE LENGTH ELEVATION LIMITS Models Pipe Size Gas Pipe Size Liquid Chargeless Length Minimum Length X Maximum Length X Maximum Height Y Additional Refrigerant mm inch mm inch m m m m g m HSNRJ25B Ø9 52 3 8 Ø6 35 1 4 10 2 20 12 15 H...

Page 9: ...t in a place where electrical wiring or conduits are located C B Ø70 A E D Wall Mounting Plate Positioning Dimensions mm HINRJ25B HINRJ35B HINRJ50B HINRJ70B HINRJ80B A B C D E A B C D E A B C D E A B C D E 294 881 228 84 43 316 940 218 54 41 316 997 217 43 38 330 1132 236 56 39 Wall Penetration Drill a Ø70mm wall penetration through the wall with a 2 to 4 fall to the outside wall Drain Pipe 1 Conn...

Page 10: ... Position the piping as shown on the drawing 3 Tape the refrigerant pipes electric cable s and drain hose Ensure the water drain hose is located at the lowest side of the bundle NOTE The drain pipe is dual handed and may be installed to either the left or right of the appliance 1 To use this option unclasp the drain hose 2 Unscrew the rubber plug from the alternate drainage discharge connection po...

Page 11: ...horised persons in accordance with AS NZS 3000 and to all other relevant local regulations and municipal building codes including OH S requirements Ensure electric wiring is installed properly Improper installation may cause malfunction fire or electric shock The unit must be earthed following local electrical codes 1 Remove the wiring cover 2 Secure the electrical cable s and power cable onto the...

Page 12: ...ocket provided 4 Re install the wiring cover CONDENSATE DRAIN INSTALLATION A condensate drainage point is provided in the base of the outdoor unit For the purposes of drainage a barbed elbow is also supplied Insert the barbed elbow into the drainage point of the outdoor unit as shown A drainage hose installer to supply will need to be fitted IMPORTANT Drainage of the condensate must conform with a...

Page 13: ...bearings etc Prior to assembly refrigeration pipes must be clean and burr free They must not be crushed or kinked For flare connections a suitable lubricant must be used between the back of the flare and the nut to avoid tearing the flare when tightening the nut Connecting Vapour Liquid Pipes To Indoor Outdoor Units 1 Align the centre of the pipes 2 Sufficiently tighten the flare nut with fingers ...

Page 14: ... and run for a minimum of 15 minutes 4 Close low pressure gauge valve manifold gauge set and turn off vacuum pump 5 Wait 2 minutes to allow pressure to stabilise then check that the low pressure gauge is maintaining a pressure of 100 kPa 76 cmHg 6 Disconnect charge hose from the vapour valve service port and replace the vapour valve service port cap 7 Open both the vapour and the liquid valves to ...

Page 15: ...ock or electrical fire Is the wiring in accordance within the specifications Operation failure electrical fire Are all inlets outlets of the indoor and outdoor units free of any obstructions No cooling or heating Are the stop valves open No cooling or heating Are the pipes designed for use with R32 Pipe or pipe connection leakage Has a leak test been carried out for the pipe connections Pipe conne...

Page 16: ...land Ltd 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Auckland 2150 Tel 09 257 3800 Toll Free 0800 764 624 For further information visit www rinnai co nz youtube com rinnainz facebook com rinnainz or email info rinnai co nz Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your ap...