background image

Rinnai 

Split AC IM

INDOOR UNIT

• 

Ensure the indoor unit is located away from 

heat or steam.

• 

Ensure the indoor unit is located so it can 

be accessed for service and replacement.

• 

Ensure the indoor unit is located so 

condensate can be drained away.

• 

Select a location where the indoor unit can 

be securely mounted.

• 

The clearances shown 

MUST BE

 

maintained.

OUTDOOR UNIT

• 

Select the location where exposure to direct 

sunlight and strong wind are minimised.

• 

Select the location where the outdoor unit 

can be securely mounted.

• 

Select the location where the noise and air 

flow will not cause nuisance.

• 

Ensure there are no obstructions in the air 

flow path.

• 

Ensure the outdoor unit is located so it can 

be accessed  for service and replacement.

• 

Do not place animals and plants near the 

air discharge.

• 

The clearances shown 

MUST BE

 

maintained.

PIPE LENGTH & ELEVATION LIMITS

Models

Pipe Size Gas

Pipe Size Liquid

Chargeless 

Length

Minimum 

Length - X

Maximum 

Length - X

Maximum 

Height - Y

Additional 

Refrigerant

mm

inch

mm

inch

m

m

m

m

g/m

HSNRJ25B

Ø9.52

3/8

Ø6.35

1/4

10

2

20

12

15

HSNRJ35B

Ø12.7

1/2

Ø6.35

1/4

10

2

20

12

15

HSNRJ50B

Ø12.2

1/2

Ø6.35

1/4

10

2

30

20

15

HSNRJ70B

Ø15.88

5/8

Ø6.35

1/4

10

2

30

20

15

HSNRJ80B

Ø15.88

5/8

Ø6.35

1/4

10

2

30

20

30

IMPORTANT

The outdoor unit is charged for interconnecting pipe lengths of up to 10m. Additional refrigerant 

is to be added for lengths above 10m.

600

300

300

1000

100

100

2000

150

150

150

1000

(All dimensions in mm)

Outdoor

unit

X

Y

Indoor

unit

X

Y

Indoor

unit

Outdoor

unit

LOCATION

Summary of Contents for HINRJ25B

Page 1: ...SNRJ70B HSNRJ80B Indoor HINRJ25B HINRJ35B HINRJ50B HINRJ70B HINRJ80B Outdoor HONRJ25B HONRJ35B HONRJ50B HONRJ70B HONRJ80B REFRIGERANT R32 J Series Split Type Wall Mounted Air Conditioner Installation Manual TURBO C LRSWING COOL SWING SPEED RUN ...

Page 2: ...ons Current AS NZS 3000 AS NZS 5141 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed only by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer s instructions ...

Page 3: ... Indoor Unit 9 Wall Mounting Plate 9 Wall Penetration 9 Drain Pipe 9 Electrical Connections 10 Wall Installation 10 Outdoor Unit 11 Electrical Connections 11 DRED Connection optional 12 Condensate Drain Installation 12 Refrigerant Pipes 13 Flaring 13 Connecting Vapour Liquid Pipes To Indoor Outdoor Units 13 Air Purging Leakage Test 14 Evacuation Vacuum Method Leak Test 14 Adding Refrigerant for Lo...

Page 4: ... or unpacking this appliance Failure to do so may result in serious injury or product failure DO NOT modify the electrical wiring of this appliance If the control power wiring is damaged or deteriorated then it must be replaced by an authorised person Failure to do so may result in electric shock fire serious injury or product failure DO NOT install the air conditioner on an unstable or non level ...

Page 5: ...formance Install the drain hose properly for smooth drainage of condensed water Make sure to check for and rectify any refrigerant leaks after you install or repair the unit This appliance uses R32 difluoromethane refrigerant which is a flammable gas class 2 2 according to AS NZS 1677 and must be handled by a refrigeration mechanic with appropriate Australian refrigerant handling licence WARNING R...

Page 6: ...he appliance off isolate the power supply and contact a service agent DO NOT operate the appliance if it has been submerged into water due to flooding contact a service agent Failure to do so may result in electric shock fire serious injury or product failure This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experie...

Page 7: ...ccess panel 7 Refrigerant pipes electrical cable s covered with binding tape 8 Condensate drain hose covered with binding tape 9 Refrigerant entry for service and installer use only 10 Outdoor unit air inlet on rear left side of unit 11 Outdoor unit air discharge and protective grille on front of unit WEIGHTS DIMENSIONS Model HSNRJ25B HSNRJ35B HSNRJ50B HSNRJ70B HSNRJ80B Weight kg Indoor 9 5 12 0 1...

Page 8: ...outdoor unit is located so it can be accessed for service and replacement Do not place animals and plants near the air discharge The clearances shown MUST BE maintained PIPE LENGTH ELEVATION LIMITS Models Pipe Size Gas Pipe Size Liquid Chargeless Length Minimum Length X Maximum Length X Maximum Height Y Additional Refrigerant mm inch mm inch m m m m g m HSNRJ25B Ø9 52 3 8 Ø6 35 1 4 10 2 20 12 15 H...

Page 9: ...t in a place where electrical wiring or conduits are located C B Ø70 A E D Wall Mounting Plate Positioning Dimensions mm HINRJ25B HINRJ35B HINRJ50B HINRJ70B HINRJ80B A B C D E A B C D E A B C D E A B C D E 294 881 228 84 43 316 940 218 54 41 316 997 217 43 38 330 1132 236 56 39 Wall Penetration Drill a Ø70mm wall penetration through the wall with a 2 to 4 fall to the outside wall Drain Pipe 1 Conn...

Page 10: ... Position the piping as shown on the drawing 3 Tape the refrigerant pipes electric cable s and drain hose Ensure the water drain hose is located at the lowest side of the bundle NOTE The drain pipe is dual handed and may be installed to either the left or right of the appliance 1 To use this option unclasp the drain hose 2 Unscrew the rubber plug from the alternate drainage discharge connection po...

Page 11: ...horised persons in accordance with AS NZS 3000 and to all other relevant local regulations and municipal building codes including OH S requirements Ensure electric wiring is installed properly Improper installation may cause malfunction fire or electric shock The unit must be earthed following local electrical codes 1 Remove the wiring cover 2 Secure the electrical cable s and power cable onto the...

Page 12: ...ocket provided 4 Re install the wiring cover CONDENSATE DRAIN INSTALLATION A condensate drainage point is provided in the base of the outdoor unit For the purposes of drainage a barbed elbow is also supplied Insert the barbed elbow into the drainage point of the outdoor unit as shown A drainage hose installer to supply will need to be fitted IMPORTANT Drainage of the condensate must conform with a...

Page 13: ...bearings etc Prior to assembly refrigeration pipes must be clean and burr free They must not be crushed or kinked For flare connections a suitable lubricant must be used between the back of the flare and the nut to avoid tearing the flare when tightening the nut Connecting Vapour Liquid Pipes To Indoor Outdoor Units 1 Align the centre of the pipes 2 Sufficiently tighten the flare nut with fingers ...

Page 14: ... and run for a minimum of 15 minutes 4 Close low pressure gauge valve manifold gauge set and turn off vacuum pump 5 Wait 2 minutes to allow pressure to stabilise then check that the low pressure gauge is maintaining a pressure of 100 kPa 76 cmHg 6 Disconnect charge hose from the vapour valve service port and replace the vapour valve service port cap 7 Open both the vapour and the liquid valves to ...

Page 15: ...ock or electrical fire Is the wiring in accordance within the specifications Operation failure electrical fire Are all inlets outlets of the indoor and outdoor units free of any obstructions No cooling or heating Are the stop valves open No cooling or heating Are the pipes designed for use with R32 Pipe or pipe connection leakage Has a leak test been carried out for the pipe connections Pipe conne...

Page 16: ...land Ltd 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Auckland 2150 Tel 09 257 3800 Toll Free 0800 764 624 For further information visit www rinnai co nz youtube com rinnainz facebook com rinnainz or email info rinnai co nz Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your ap...

Reviews: