Installation & Servicing Instructions E-Range
33
15 Technical specifications
Technical specifications
Table 9
Boiler type
E32S
Input Hs CH
kW
32
Q
n
Output Hi CH
kW
28.8
Efficiency class according BED
Efficiency according EN677
(36/30°C part load. Hi)
%
109.9
Efficiency according EN677
(80/60°C full load. Hi)
%
97.9
Modulation range CH
(capacity 80/60°C)
kW
6.1 - 28.2
Modulation range CH
(capacity 50/30°C)
kW
6.8 - 30.6
Nox class EN483
5
CO
2
%
9
Temperature class for PP flue
T100
Appliance type
C13 C43 C53 C63 C83
Flue gas temp. CH
(80/60°C on full load)
°C
68
Flue gas temp. CH
(50/30°C on low load)
°C
31
Categories
II2L3P
Gas consumption G20 CH (DHW)
(at 1013 mbar/15°C)
m
3
/h
3.05
Electr. power consumption max.
W
145
Electr. power consumption stand by
W
10
Current
V/Hz
230/50
Fuse rating
A
5
Degree of protection acc. EN 60529
IPX4D
Weight (empty)
kg
40
Width
mm
500
Height
mm
870
Depth
mm
395
Water content CH
l
5
After run time pump CH
min
19
After run time pump DHW
min
P
MS
Water pressure min./max.
bar
1/3
Flow temperature max.
°C
85
Pump type
UP20-60
Available pump height CH
kPa
17
CE product identification number(PIN)
0063BR3409