ACCEPTABLE VENTING CLEARANCES FOR IPEX CONCENCTRIC VENT KIT (CVK) TERMINATION:
Figure 11a: T
WO
OR
M
ORE
V
ENT
T
ERMINALS
ON
SAME
LEVEL
Figure 11b: Vertical between Terminals
Vent spacing depicted above are specific to IPEX PVC/CPVC- FGV Concentric Vent Kit
ONLY
; for required
spacing for all other termination types, refer to Figures 12 thru 16.
NOTE
Reference “General Clearance
Requirements” section of this guide
for important considerations for
locating vent termination under a
soffit (ventilated or unventilated),
eave, or deck/porch.
Soffit
CVK
Ceiling
24” MIN
to next CVK
60” MIN
to next CVK
12” Above anticipated
snow level or grade