3PH Auxiliary Relay Box OIM

IMPORTANT

The 3-phase auxiliary relay box must be directly connected to a 415 V AC 50 Hz mains power 

supply. The 3-phase auxiliary relay box must be on its own circuit with an isolating switch installed 

at the switchboard. A secondary isolating switch must be installed within reach of the box. 
Connect all 

ACTIVE

 and 

NEUTRAL

 wires in accordance with the wiring diagram. Ensure the 

incoming 

EARTH

 wire is securely fixed to the earth post. 

NOTE

Select suitable cable size according to the electric element capacity of the tank. Normally each 

3-phase auxiliary relay box works with one electric tank.

AUXILIARY BOOSTER SIGNAL

Wire terminals “3” and “4” to heat pump with a minimum 0.75mm

2

 two-core cable (provided by installer). The cable 

length should be less than 10 metres. 

POWER SUPPLY TO ELECTRIC TANK 

Connect all active, neutral and earth wires directly from the contactor or terminals and wire to electric tank. Normally 

each 3-phase auxiliary relay box works with one electric tank. Refer to the electric tank wiring diagram for tank 

wiring. 

L1 L2 L3 

N

L1 L2 L3 N

3  4

To Electric Tank

To Heat 

Pump

Main Power Supply

BASIC OPERATION

Summary of Contents for CHP3PHAUX

Page 1: ...3HP Auxiliary Relay Box Operation Installation Manual MODEL CHP3PHAUX ...

Page 2: ...tallation read this manual thoroughly and gain a full understanding of the appliance to ensure safe and correct use IMPORTANT NOTICE FOR INSTALLERS Please leave these instructions with the end user after commissioning of the system and alert the end user of the content sections Warnings and Periodic Inspection and Maintenance This appliance must be installed in accordance with Manufacturer s Insta...

Page 3: ...s full of water NEVER use a flammable spray such as hair spray paint etc near this unit as this may cause a fire At the end of the service life of the heat pump water heater and prior to being disposed of a person qualified with refrigerant handling must recover the refrigerant from the system The refrigerant must not be vented to atmosphere Please call our National Help Line to arrange for an ins...

Page 4: ...7 C Heat pump and auxiliary booster may work simultaneously When ambient temperature falls below 0 C heat pump is deactivated Heat pump won t activate until the ambient temperature reaches above 2 C Only the auxiliary booster will operate until the set point reaches When heap pump is in fault auxiliary booster will operate instead of the heat pump until the set point reaches Auxiliary booster will...

Page 5: ...elect suitable cable size according to the electric element capacity of the tank Normally each 3 phase auxiliary relay box works with one electric tank AUXILIARY BOOSTER SIGNAL Wire terminals 3 and 4 to heat pump with a minimum 0 75mm2 two core cable provided by installer The cable length should be less than 10 metres POWER SUPPLY TO ELECTRIC TANK Connect all active neutral and earth wires directl...

Page 6: ...Rinnai 6 3PH Auxiliary Relay Box OIM ELECTRICAL DIAGRAM WIRING DIAGRAMS WIRING DIAGRAMS ...

Page 7: ...NO MAIN POWER SUPPLY 415V 50Hz SUPPLY TO TANK 415V 50Hz N L1 L2 L3 N GLAND MAIN ISOLATOR 415V 50Hz Auxiliary Contactor Auxiliary Contactor Auxiliary Contactor Electric Tank Electric Tank Electric Tank CHP3PHAUX CHP3PHAUX if provided CHP3PHAUX if provided TO HEAT PUMP TERMINAL 3 4 WIRING DIAGRAMS ...

Page 8: ...Tel 1800 000 340 Cost of a local call may be higher from a mobile phone National calls from public phones in Australia are free For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call o...

Reviews: