Arriva 752 Operation Guide: 12219-A 01-12

Troubleshooting

Characteristic

Explanation

when turning 

on

warm air does not start when the burner 

lights.

The fan starts automatically after a short delay. 

This is to allow the appliance to warm up, 

helping avoid cold draughts.

Smoke or strange smells are produced 

when first operating the appliance after 

installation.

This is caused by grease, oil, or dust within the 

appliance. This will stop after a short time.

Sharp clicking noises at ignition, or when 

the unit thermostat modulates to a lower 

or higher setting, or shuts down.

This is expansion and contraction of the heat 

exchanger and is a normal part of operation.

During 

operation

Clunking noise when the thermostat 

operates

This is the sound of the gas valve opening and 

closing to regulate the flow of gas.

when turning 

off

Fan continues to run after the heater is 

turned off.

This is to remove residual heat from within the 

appliance. This stops once the unit cools down.

Other

Steam is discharged from the flue terminal 

outside.

High efficiency appliances tend to discharge 

water vapour on cold days—this is normal.

Heater doesn’t start when the Standby/On 

button is pushed (thermostat on high)

Check the appliance On/Off button is on. Check 

timer(s). Timer programmes must be turned off 

or overridden for manual operation.

Timers

Timer(s) do not operate at the set time

They may be inactivated or incorrectly 

programmed. Check timers are set correctly.

Timer operates for a short time then cuts 

out

Room temperature may be higher than the set 

temperature. Increase set temperature if desired. 

Turn off the Extra Low button if on.

Check the following information before making a service call as some performance characteristics of 
the Arriva are a normal part of operation. If you are still unsure or concerned after reading this section, 
please contact Rinnai.

During installation there will be an initial burning in period where some smoke and smell may be 
experienced. This is a normal part of the operation. 

 
The appliance is fitted with an overheat safety switch. under overheating conditions this switch will 
shut off the appliance. If the appliance shuts off repeatedly servicing may be required.

Using the heater for the first time, or after a long period of non use

Ignition may not occur the first time it is operated due to air in the gas pipes. If ignition does not occur 
within approximately one minute the appliance will attempt to re-light. If ignition does not occur the 
unit will switch off automatically. Try operating the heater again if this occurs.

The heater may make noises after ignition or switching off. This is due to the expansion and contraction 
of the internal components—this is normal. The heater will not ignite if the On/Off button is pressed 
straight after the heater has turned off. It will take approximately 20 seconds before the unit will switch 
on again.

Summary of Contents for Arriva 750

Page 1: ...Arriva 752 Operation guide ...

Page 2: ...d personnel Please retain this manual for future reference Warning Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life For more information about buying living and servicing of Rinnai appliances call 0800 RINNAI 0800 746 624 Rinnai New Zealand Limited 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Auckland ...

Page 3: ...ral information 7 Operation without the remote 8 Operation using the remote 9 Care of your Arriva 752 11 Maintenance and servicing 12 Troubleshooting 14 Error codes 16 Abnormal flame pattern 17 Installation checklist 18 Installer details 18 Limited warranty 19 ...

Page 4: ...sumption Auto overheat discharge vent Room air return Louvre warm air discharge Room air return Burn media Blockage indicator for filter and louvre blockages Double glazed frame window Control panel Room air return Remote receiver window for infra red remote 5 m range Error display Displays error codes Operation indicator Indicates operation status Timer indicator Indicates timer program status On...

Page 5: ...ce while it is in operation Do not restrict warm air discharge by placing articles in front of the appliance This appliance must not be used for any other purpose other than heating Children should be supervised at all times to ensure they do not play with the appliance Hand or body contact with the appliance must be avoided Do not allow anyone to sit lean or sleep directly in front of the applian...

Page 6: ... occurring it is recommended that a mat be placed in front of the appliance Mantels and surrounds Mantels and surrounds are allowed providing they conform to the minimum clearances shown These clearances are important as they allow heat to escape in the event of a power failure during operation allow optimum performance of the heater room air return allow access to the side mesh filters Clearance ...

Page 7: ...he Arriva 752 close to the floor The unit can be fully recessed as long as the mantel and surround clearances on the previous page are maintained Power failure If the power is disrupted while the heater is operating once the power is restored the heater will go into power failure mode on the control panel there will be flashing zeros in the error display and the LED will flash green To reset the h...

Page 8: ...s will flow to the main burner 3 When the main burner has established the heater will automatically modulate between the burner settings to achieve and maintain the default set temperature of 22 C If the heater is turned off using the On Off button on the heater control panel when it is turned back on it will lose any timer and clock settings until the remote is used to re transmit the information...

Page 9: ...nd beep to confirm the settings have been received Batteries The remote uses two x 1 5 V AAA batteries Never mix old and new batteries Remove the batteries if the remote is not going to be used for a long time This will help avoid damage from leaking batteries Standby On Stops and operates the heater remotely Flame Sets the flame picture Extra low Energy saving room temperature control Lock Locks ...

Page 10: ...s achieved by sensing the room temperature one hour prior to start Override This is used to manually override the timers so the heater can be operated outside of the timer settings When override is selected Override will be displayed While in override mode all remote control functions except for the flame function are available until the next timer setting is reached To return to the timer setting...

Page 11: ...ashing red When a build up is detected the blockage indicator LED located above the receiver window will begin to flash red to let you know there is a problem Once the indicator light is flashing if no action is taken the heater will eventually shut down to avoid overheating Error code 14 will be displayed in the error display window on the control panel of the unit Returning the appliance to norm...

Page 12: ...ces should be serviced every two years including inspection of the flue system If they are in a particularly dusty environment or subject to excess lint for example dog hair or where there are newly laid carpets then annual servicing would be beneficial Regular maintenance servicing is not covered by the Rinnai warranty Do not attempt to carry out any service work other than that mentioned in the ...

Page 13: ...Arriva 752 Troubleshooting error codes ...

Page 14: ...not operate at the set time They may be inactivated or incorrectly programmed Check timers are set correctly Timer operates for a short time then cuts out Room temperature may be higher than the set temperature Increase set temperature if desired Turn off the Extra Low button if on Check the following information before making a service call as some performance characteristics of the Arriva are a ...

Page 15: ...ns power failure Use power failure reset procedure p 7 Air in gas pipe when initially installed Installer to purge air from gas supply Filter obstructed Remove and clean filters Gas escape Isolate gas supply and contact Rinnai for a Service Centre Timer set Use override button Lock set Cancel lock Gas supply turned off Turn gas supply on at the meter or cylinder Flat batteries Replace batteries in...

Page 16: ...required 12 Incomplete combustion As above 14 Filter blockage overheat Clean filters if error continues a service call is required 16 Room overheat Lower room temperature to below 40 C 31 Room temperature sensor faulty Service call 32 Overheat temperature sensor faulty Service call 33 Overheat temperature sensor faulty Service call 53 Spark sensor faulty Service call 61 Combustion fan motor faulty...

Page 17: ...ed from when the fire was first installed There are some warning signs that could indicate a problem Unusual smell from the appliance Continued difficulty or delay in establishing a flame Flame appears either very short or very long Flame only burns part way across the burner Severe soot building up on the inside of the glass door1 If any of the above signs occur please call Rinnai to discuss Norm...

Page 18: ...ion clearances mantels surrounds etc F F Rinnai flue system installed and tested to ensure effective draw F F Gas pressure checked set and down rated if applicable according to data plate instructions F F Burn media installed as per instructions F F Appliance tested for correct operation and to ensure no gas leaks F F Customer instructed on operating procedure and safety requirements F F Customer ...

Page 19: ...ge or abuse beyond that expected from conditions of normal use 3 Warranty claims may be invalid if not accompanied by details of the installing or supervising gas fitter s registration number and the gas fitting certification number 4 This warranty commences from the date of purchase Proof of purchase is required at the time of any warranty claim 5 Servicing of the product is to be carried out by ...

Page 20: ...Rinnai co nz Experience our innovation 0800 746 624 https www youtube com rinnainz ...

Reviews: