E-2/3 Error code |Outlet temperature sensor
If you unit is displaying an E2/3 error code. Your unit is notifying you the outlet
temperature sensor is not reading correct Temperature and may need to be check and
replaced. In order to resolve this issue please follow the below steps.
By passing E2 Error Code
Remove PCB cover
Check if terminal loose or not,replace terminals accordingly.
Remove thermal sensor anti-clockwise
Restore new sensor in reverse sequence and re-connect
Check terminal loose or not
Right order as shown in the pictures below
If the temperature limiter does not reset manually, it needs to be replaced
Right order as shown in the pictures below
1.Remove temperature limiter and inside terminal screws
2.Replace temperature limiter
3.Connect and secure with screws
4. Check screws loose or not.
Right order as shown in the pictures below