6
Ring Alarm Keypad – Exclusion
Removing Ring Alarm Keypad from a Z-Wave Network
Exclusion Instructions:
1. Initiate remove “Ring Alarm Keypad” flow in the Ring Alarm mobile application – Select the settings
icon from device details page and choose “Remove Device” to remove the device. This will place the
controller into Remove or “Z-Wave Exclusion” mode.
2. Locate the pinhole reset button on the back of the device.
3. With the controller in Remove (Z-Wave Exclusion) mode, use a paper clip or similar object and tap
the pinhole button. The device’s Connection LED turns on solid red to indicate the device was
removed from the network.
Ring Alarm Keypad – Factory Reset
Factory Default Instructions
1. To restore Ring Alarm Keypad to factory default settings, locate the pinhole reset button on the
device. This is found on the back of the device after removing the back bracket.
2. Using a paperclip or similar object, insert it into the pinhole, press and hold the button down for
10 seconds.
3. The device’s Connection icon LED will rapidly blink green continuously for 10 seconds. After about 10
seconds, when the green blinking stops, release the button. The red LED will turn on solid to indicate
the device was removed from the network.
Note
Use this procedure only in the event that the network primary controller is missing or
otherwise inoperable.
Wake-Up Notification
Not applicable. Ring Alarm Keypad (LSS) is a Frequently Listening Receiver Slave (FLiRS) device and
does not support Wake Up Command Class.