September 2018 Operations Manual RM5000EX
TWO STAGE EX500
Two EX500 are interconnected to form one system. One to four audio links and one RS485 data
link are used to connect the two centrals.
PROGRAMMING
STAGE 1 (address $08):
1. Default System Memory to Stage 1 with 3 call digits (page 38).
2.
Set Network Address = 08 (page 37)
3.
Push Reset Button
4.
Program Interlinks
Interlink1
Interlink2
Interlink3
Interlink4
Set device type ILK SDT 183 6
SDT 184 6 SDT 185 6
SDT 186 6
Set remote net
SNA 183 4 09
SNA 184 4 09 SNA 185 4 09 SNA 186 4 09
Set remote line equ. SNA 183 5 3A
SNA 184 5 3B SNA 185 5 3C SNA 186 5 3D
STAGE 2 (address $09):
1. Default System Memory to Stage 2 with 3 call digits (page 38).
2. Set Network Address = 09 (page 37)
3. Push Reset Button
4. Program Interlinks.
Interlink1
Interlink2
Interlink3
Interlink4
Set device type ILK SDT 283 6
SDT 284 6
SDT 285 6
SDT 286 6
Set remote net
SNA 283 4 08
SNA 284 4 08
SNA 285 4 08
SNA 286 4 08
Set remote line equ. SNA 283 5 3A
SNA 284 5 3B
SNA 285 5 3C
SNA 286 5 3D
Push Reset Button on Stage 1 and Stage 2
Page45