![RinG-MASTER RM5000EX Operation Manual Download Page 40](http://html.mh-extra.com/html/ring-master/rm5000ex/rm5000ex_operation-manual_1462265040.webp)
RM5000EX Operations Manual September 2018
Multi stage:
SW2 1 and 2 on PCB500 (EX500) is used for selecting number of digits in call numbers when the
system is defaulted.:
1
2
OFF
OFF
Reserved
OFF
ON
2 Digit Dialing (10-55)
ON
OFF
3 Digit Dialing (100-155)
ON
ON
4 Digit Dialing (1000-1055)
1.
Set SW3 1 and 2 to OFF
2.
Set SW2 1 and 2 to number of call digits to 2,3 or 4
3.
Set SW2 4–8 for stage number (1-9)
4.
Push and release the Reset Switch on EX500 (SW4).
5.
Turn on SW3 1
6.
Set SW2 (EX500) to proper network address Push and release the Reset Switch on EX500
(SW4).
LED M (EX500) will blink 4 times during RAM Test .
The system is now operational.
DEFAULT CALL NUMBERS
SW2 4 5 6 7 8
STAGE
PORT
SW2 1 2
SW2 1 2
SW2 1 2
o 1
1 o
1 1
1 o o o o
1
00-37
38-3D
10-65
81-86
100-155
181-186
1100-1155
1181-1186
o 1 o o o
2
00-37
38-3D
10-65
81-86
200-255
281-286
1200-1255
1281-1286
1 1 o o o
3
00-37
38-3D
10-65
81-86
300-855
381-886
1300-1355
1381-1386
o o 1 o o
4
00-37
38-3D
10-65
81-86
400-455
481-486
1400-1455
1481-1486
1 o 1 o o
5
00-37
38-3D
10-65
81-86
500-555
581-586
1500-1555
1581-1586
o 1 1 o o
6
00-37
38-3D
10-65
81-86
600-655
681-686
1600-1655
1681-1686
1 1 1 o o
7
00-37
38-3D
10-65
81-86
700-755
781-786
1700-1755
1781-1786
o o o 1 o
8
00-37
38-3D
10-65
81-86
800-855
881-886
1800-1855
1881-1886
1 o o 1 o
9
00-37
38-3D
10-65
81-86
900-955
981-986
1900-1955
1981-1986
Gray area not recommended
Page40