1

 

Minidyn description 

1.1

 

Hardware description 

The lightweight deflectometer (LWD) Minidyn is available in different versions depending 

of the fabrication date: 

-

 

Up do 2013 

: Minidyn version 1 

-

 

From 2014 to 2016 

: Minidyn version 2 

-

 

Since 2017 

: Minidyn version 3 

-

 

Since 2019  

: Minidyn version 4 

-

 

Since 2020  

: Minidyn version 5 

-

 

Since 2021 

: Minidyn version 6= 

 

Figure 1: Lightweight deflectometer. Version 3 (left), 2 (middle) and 1 (right). 

 

Versions  2  and  3  improve  the  ergonomic  and  aesthetic  of  the  Minidyn.  The  use  of  the 

Minidyn both software and hardware are the same regardless of the version. Performances 
and results are also the same. 

 

Summary of Contents for Minidyn V9

Page 1: ...bis rue du bois briard 91080 Courcouronnes T l 09 72 32 45 98 E mail rincent ndt rincent fr SARL au capital de 300 000 euros n de SIREN 431 715 689 Rincent Minidyn LightWeigth Deflectometer User manu...

Page 2: ...Rincent ND Technologies Minidyn User Manual Page 2...

Page 3: ...1 Modulus calculation steps 17 2 2 Stiffness calculus algorithms 18 2 2 1 Max method 18 2 2 2 Integral method 18 2 2 3 Method comparison 20 2 3 Boussinesq formulae 20 2 4 Correlation algorithms 21 2...

Page 4: ...Rincent ND Technologies Minidyn User Manual Page 4 3 6 2 Project and report selection 29 3 6 3 Make a measurement 29 3 7 Exportation 30 4 Warranty 31...

Page 5: ...rsion 1 From 2014 to 2016 Minidyn version 2 Since 2017 Minidyn version 3 Since 2019 Minidyn version 4 Since 2020 Minidyn version 5 Since 2021 Minidyn version 6 Figure 1 Lightweight deflectometer Versi...

Page 6: ...e is autonomous and send measurement date via USB or Bluetooth User can either Connect to the case using USB cable and Minidyn software on Windows Connect to the case using Bluetooth using an Android...

Page 7: ...The Minidyn instrument is separated in two different part Measurement plate with sensors and acquisition Guiding rod with falling weight and elastomer buffer Assembling the Minidyn is done by sliding...

Page 8: ...cm to 100 cm Environment IP65 20 C to 40 C Load cell Strain gauge Max load 25 kN Error 0 3 FS Displacement sensor Vertical geophone Frequency range 4 5Hz 2500Hz Resolution 1 m Modulus range 10 Kg wei...

Page 9: ...hoc resistant Screen 4 WVGA Data transfer Email using Wi Fi or 3G Direct transfer using USB Storage capacity 100 000 measures Software installed Minidyn Android Functions Acquisition et review Connect...

Page 10: ...Minidyn in two parts and take one part in each hand Figure 4 Transport de la Minidyn Since version 2 the Minidyn can be transported in one piece using the handle at the base of the plate 1 4 Drop wei...

Page 11: ...ng of the weight Figure 6 10 kg configuration with 3 buffers left 20kg config with 5 buffers right 1 5 Acquisition case 1 5 1 Description The acquisition cases for all Minidyn version have the same fu...

Page 12: ...e Minidyn If unused the Minidyn automatically power off after 15 minutes The Minidyn status led has several states Short blink The Minidyn is powered and wait for a Bluetooth or USB connection Slow bl...

Page 13: ...rger for car or AC wall plug An USB port of a computer The stats for the battery red led are During normal use o Slow blink The battery is low The Minidyn will shut down in about 15 to 30 minutes o Fa...

Page 14: ...is on the ground rotate the Minidyn back and forth using the handles to ensure a uniform contact with the ground Figure 8 Moving the plate to make a good contact 1 6 2 Make a test point Use the Minidy...

Page 15: ...the palm of your hand If not the plate can bounce from the ground and make erroneous measurement Do not make two measurements at the same spot The first measurement will compact the ground and the se...

Page 16: ...axis It is recommended to transport the Minidyn in two part one part in each hand Figure 10 Maximum stress for load cell 1 7 2 Weather You can use the Minidyn under light rain The acquisition box and...

Page 17: ...eps used for modulus calculation Figure 11 Modulus calculation steps The digitized load and speed measurements from the sensors are filtered using a low pass filter of about 500 Hz Speed is the integr...

Page 18: ...the ratio of maximum load to the maximum deflection Figure 12 Max method 2 2 2 Integral method The integral method is a method that take into account the dynamic parameters of the ground This method...

Page 19: ...n also calculates a quality index Iq of the measurement This quality index is obtained calculating the difference between the measured signal and the simulated signal using the m c k parameters that w...

Page 20: ...ulated the dynamic behavior of the ground the resulting stiffness is lower that the stiffness calculated using Integral method Bias form 10 to 20 is observed and have to be taken into account during t...

Page 21: ...correlation Linear correlation is used primarily to obtain an equivalent modulus on a restrained modulus value range and for a given platform Coefficient K is typically comprised between 1 and 2 Coeff...

Page 22: ...0 60 80 150 180 K 1 33 1 60 2 00 2 00 2 14 2 25 Tableau 3 Correlation table ZTVE STB 94 The Minidyn software include an exponential correlation with the EDYN2 equivalent modulus NFP 94 117 2 standard...

Page 23: ...ogle play store 3 1 2 Bluetooth pairing Pairing must be done between your smartphone and Minidyn before making measurement Steps can vary from Android version for example here are the procedure for 4...

Page 24: ...Minidyn Bluetooth is in majuscule and without space RNDTBT Figure 17 Pairing the Minidyn 3 1 3 Fist launch At first launch it is recommended to change Default operator name Modulus calculation paramet...

Page 25: ...tions The information of the current project Navigation button Figure 18 Main interface 3 3 Settings Setting are change using the Setting button If a project is already loaded a windows will pop up to...

Page 26: ...s open you can change the way the modulus is calculated and all the measurements will be reprocessed accordingly 3 3 2 Acquisition configuration Number of drop per points Several drop of the weight ar...

Page 27: ...default Software configuration Operator Name of the person or company that do the measurements Demo mode The demonstration mode simulate a fake Minidyn hardware and measurements are software generated...

Page 28: ...the name of the project is mandatory in the information tab Figure 20 Projects tabs 3 5 2 Report The Report button is activated when a project is selected As for the project you can select or create a...

Page 29: ...To do test points just touch the Measure button and a temporary project a report will be created 3 6 2 Project and report selection To save measurement you have to create a PV and a report 3 6 3 Make...

Page 30: ...n done use the stop button to finish the measurement 3 7 Exportation Exportation is used to send all the project information and measurements to an email or a file to be read afterward on the Minidyn...

Page 31: ...essories have a one year warranty Every degradations resulting from an improper use of the instrument or its accessories are not warrantied form example but not limited to Degradation caused by a fall...

Page 32: ......

Page 33: ......

Page 34: ......