Rincent ND Technologies
Minidyn User Manual
Page 14
1.6
Measurement
1.6.1
Preparation
The ground where is put the Minidyn need to be homogenous. It is recommended to add
a fine layer of sand to level the ground.
When the plate is on the ground, rotate the Minidyn back and forth using the handles to
ensure a uniform contact with the ground.
Figure 8 : Moving the plate to make a good contact.
1.6.2
Make a test point
Use the Minidyn software to start an acquisition
Put the palm of one hand on the upper handle while moving up the weigth with the other
hand. Drop the weight when it is at maximum height. Start again as needed to make one
point (3 by default).