The definition of word to be used in this manual. 

Measuring gas 

Target gas to measure in sample gas 

Base gas 

Remaining gas excluding measuring gas in sample gas. 

Reference gas 

The  gas  to  be  used  as  the  basic  standard  gas  to  measure  gas 

concentration. 

Normally the base gas is used as reference gas. 

Reference gas 

calibration 

(REF CAL.) 

Adjusting work of reading when reference gas concentration is 

measured. 

 

       

The definition of word to be used in specification sheet. 

Vol % 

This  is  the  unit  shown  by  percentage  for  how  much  a  specific 
substances(or gas) in a volume is occupied in that volume. 

p p m 

This is the unit showing a volume at a part per million. 
(1 vol% = 10,000ppm) 

% LEL 

This is the unit to define the lower explosive limit of combustible 
gas as 100% 

mg/L 

This  is  the  unit  showing  a  weight  in  1  liter  of  objective  gas  for 
measurement. The value is based on 101.3kPa at 20℃. 

MJ/m3 
Gross 

This  is  the  unit  of  calorie  and  is  shown  as  Gross  Corific  Value 
0℃. The Gross Calorific Value 0℃  is a unit of calorie commonly 
used in city gas companies, which shows the generating calorie 
when  1m3  gas  is  made  perfect  combustion  at  normal 
condition(0℃, 1 atm). 
The  gas  combustion  produces  water  vapour,  but  the  Gross 
Calorific  Value  applies  the  one  adding  the  calorie  of  water 
vapour (latent heat) 

MJ/m3 
Net 

This is the unit of calorie and is shown as Net Corific Value 0℃. 
The Net Calorific Value 0℃  is a unit of calorie commonly used 
in city gas companies, which shows the generating calorie when 
1m3  gas  is  made  perfect  combustion  at  normal  condition  (0℃, 
atm). 
The  gas  combustion  produces  water  vapour,  but  the  Net 
Calorific  Value  applies  the  one  adding  the  calorie  of  water 
vapour (latent heat) 
 

Gross calorific value = Net calorific value + latent heat 

 
 

 

 

 

This analyzer does not employ harmful substances(materials) for environment. 

Treat it in accordance with the local regulations when scrap this analyzer. 

7.Scrap of the product 

6. Definition of word 

Summary of Contents for FI-800

Page 1: ...be used for any other purpose than what is specified in this manual 4 Follow all the instructions in this manual an deviation will compromise the safety quality and performance of this instrument 5 We...

Page 2: ...k for use of the FI 800 All persons who use this analyzer for the first time and who has ever used the analyzer are requested to read through the manual to understand the content before use This manua...

Page 3: ...t display of interferometric sensor 10 Adjustment of 4 20mA output 11 Sensitivity Span adjustment of the sensor 11 Setting of alarm levels 12 Alarm test 13 Setting of AUTO REF CAL CYCLE Option 14 Disp...

Page 4: ...r use Accessory Control key The control key used for adjustment is made from a powerful magnet If it is closed to a credit card ID card other magnet products this key may damage the stored data Functi...

Page 5: ...maintenance mode BRIGHT light Illuminates when light source amount of interferometric sensor is displayed Flickers when light source amount is decreased CONT light Illuminate when contrast of interfe...

Page 6: ...EF IN respectively When 3 way cock etc is installed separately change the cock position to supply the gas See Installation work manual for piping method using 3 way cock 6 Adjust sample flow rates of...

Page 7: ...alarm patterns such as H HH alarm L LL alarm and L H alarm Each alarm action has the 1st alarm point AL1 and the 2nd alarm point AL2 which are activated when below conditions are covered The mark X i...

Page 8: ...sensor deterioration during selfdiagnosis or measurement BRIGHT light and or CONT light flashes to show the deterioration of the sensor Flashing of BRIGHT light This is a cautional indication for the...

Page 9: ...main PC board is required E 01 This means the interruption of measurement due to the deterioration of inteferometric sensor Flashing of BRIGHT light means the decrease of light amount for light sourc...

Page 10: ...approx 2 5mA and REF CAL light flashes Also the menu shown at right side is displayed on LCD display part You can step to each menu by pressing UP DOWN switch and mark of SET switch The below table s...

Page 11: ...placement interval of the interferometric sensor can be guessed by checking the contrast level When mark of MAINTENANCE switch is pressed it returns to 3 Light amount display of interferometric sensor...

Page 12: ...pressed during is displayed Pressing SET switch again LCD flashes and SPAN LED turns on to show that the span adjustment is ready Supply pre known standard gas and adjust indication with switch Press...

Page 13: ...l and 2nd alarm level respectively Pressing SET switch during 1st alarm level or 2nd alarm level is displayed LCD flashes and it is possible to change the setting with switch Pressing mark of MAINTENA...

Page 14: ...o level on LCD display flashes If alarm contact is set to both CONT light and SPAN light flash It is possible to change the test level between 0 full scale or over scale by pressing switch or switch 4...

Page 15: ...ET switch during is displayed specification number our control No of FI 800 is displayed This function is to confirm by field service engineer and is not important function for user Pressing mark of M...

Page 16: ...ake Reference gas calibration Confirmation of sample flow rate to GAS IN and REF IN Check that 300 25ml min is supplied to both GAS IN and REF IN If not adjust it to 300 25ml min respectively Also che...

Page 17: ...works by making alarm test Every 6 months 12 months inspection Item Countermeasure Gas sensitivity adjustment Calibration After making reference gas calibration supply the pre known calibration gas f...

Page 18: ...ks in normal Treatment for storage or long time shutdown 1 When FI 800 is not used for a long time remove the measuring gas especially solvent gases and vapors inside pipings by blowing the fresh air...

Page 19: ...ears 2 pcs 7 Flowmeter ass y Including low flow sensor 1 year 7 8 years 2 sets The replacement interval will change depending on operating conditions and it does not mean the guarantee period Replacem...

Page 20: ...eference gas is contained This analyzer cannot measure the gas correctly if other gas is contained Water vapor is condensated in piping and measuring gas is melted in condensated water Change the inst...

Page 21: ...101 3kPa at 20 MJ m3 Gross This is the unit of calorie and is shown as Gross Corific Value 0 The Gross Calorific Value 0 is a unit of calorie commonly used in city gas companies which shows the genera...

Page 22: ...t 125VAC 30VDC Resistive load Self diagnostic function Low sample flow decrease of light amount for interferometric light source decrease of interferometer contrast Power requirement 100VAC 10 220VAC...

Page 23: ...nsor The image of interference fringes is photographed by image sensor and the amount of the movement is measured with Fourier analysis technique And the result is converted to the refractive index Co...

Reviews: