background image

|

13

EN

12

6. ASSEMBLY/DISMANTLING STONE AND OPTIONS

Note

Only work on the unit when the mains plug has been disconnected and the 

stove has cooled completely.

Note

During assembly / dismantling do not allow objects (screws etc.) to fall into 

the pellet container – they can block the screw conveyor and damage the 

stove.

Note

During any conversion work, take particular care of your fingers and any 

panels and stove attachments.

Select soft bases to prevent scratches to your living space furniture and 

stove panels.

Disassembly of the front side casing

Remove the convection fins by lifting slightly. The convection fins are only 

suspended.

Now remove the upper hexagon screw on the front stone holder and loosen 

the bottom two.

You can now lift the front stone.

Now remove the 8 hexagonal screws used to attach the two side stone holder. 

You can then remove the side stones.

Install the removed parts in reverse order.

Disassembly of the rear side panel

Open the container lid.

Remove the 2 vertical hexagonal screws used to attach the right rear side 

panel.

You can now lift the right rear side panel.

Install the removed parts in reverse order.

The disassembly of the left rear side panel is analogous to removing the right 

rear side panel.

#8

#8

#8

Summary of Contents for REVO TOUCH

Page 1: ...Operating Manual REVO TOUCH...

Page 2: ...ellet container refilling during operation 10 Pellet storage 10 4 TECHNOLOGY AND SAFETY FUNCTIONS 11 Operating comfort 11 Top efficiency lowest emissions 11 Overheating 11 Low temperature shutdown 11...

Page 3: ...ng of the burn pot daily 15 Cleaning the flame temperature sensor 15 Empty the ash drawer 15 Cleaning the door glass 15 Cleaning painted surfaces 15 9 CLEANING 16 Cleaning the convection air openings...

Page 4: ...Spare part overview exploded diagram...

Page 5: ...5 EN 4...

Page 6: ...ound sealing strip grey D11 40 N111825 Door contact switch 41 L01777 Rear wall grey L01812 Rear wall black 42 N103066 Round sealing strip black D06 43 B16155 Induced draft fan housing B15913 Induced d...

Page 7: ...acity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to s...

Page 8: ...g non heat resistant objects on the stove or near it is prohibited Q Q Do not place clothing on the stove to dry Q Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER...

Page 9: ...type 1 BA 1 Q Q Suitable for multiple occupancy Note the different country regulations Q Q These may only be operated with the combustion chamber door closed Q Q The combustion chamber door is to be...

Page 10: ...th a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel manuf...

Page 11: ...creasing the operational safety The status indicator CLEANING appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic cleaning cycle is pe...

Page 12: ...384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspection and cleaning must be present The flue p...

Page 13: ...ly of the front side casing Remove the convection fins by lifting slightly The convection fins are only suspended Now remove the upper hexagon screw on the front stone holder and loosen the bottom two...

Page 14: ...ontrol of your stove is to be assumed by an external room thermostat you have to connect your external room thermostat 1 instead of the standard integrated cable bridge 2 The connected room thermostat...

Page 15: ...he burn pot The burn pot can be easily cleaned inside the stove After removing the pot the area underneath can be vacuum cleaned 1 V V V V V V V V V V V vvvv vvvvv V v v v v Do not damage the ignition...

Page 16: ...rs FIRE RISK Cleaning the pellet container Do not refill the completely empty container immediately remove the residues dust chippings etc from the empty container The unit must be disconnected from t...

Page 17: ...of your pellet stove replace any defect porous frayed seals after cleaning and maintenance Cleaning the flue pipes annually Remove the flue pipes Inspect and clean the chimney connection Brush off any...

Page 18: ...CLEANING and MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Q Burning in phase taking into service Q Q Stove has accumulated dust and or dirt Possible solutions Q Q Wait to e...

Page 19: ...These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points...

Page 20: ...aged Serial number Operating instructions Software version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present...

Page 21: ...nuals valid at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the clai...

Page 22: ......

Page 23: ...23 EN 22...

Page 24: ...lid one Technical and design changes as well as typesetting and printing errors reserved 2019 RIKA Innovative Ofentechnik GmbH Z35958_EN_Revo_Touch 2 04 2019 RIKA Innovative Ofentechnik GmbH M llervie...

Reviews: