Safety clearances

Note

In the inside space the pellet stove insert must be surrounded by 

incombustible

 materials.

The following safety clearances must be observed in the inside space:
b-e > 50mm, c-e > 50mm

The following safety clearances must be observed from the front:
a > 400mm (to non-combustible objects) 
a > 800mm (to combustible objects)

Note

When being installed in a recess, the overhang may be a maximum of 20cm.

Note

The sections for circulating air and supply air, as prescribed in the “Fachregeln des Ofen- und Luftheizungsbauerhandwerks TR-OL 2006” 
(rules of the tiled stove and air heating system builder trade) must be observed. A supply air section of 200cm2, and a circulating air section 
of 200cm2 have already been provided in the appliance.

Installation variants 

(minimum dimensions of inside space)

A

Left side flue connection

B

Rear side flue connection

C

Right side flue connection

>50cm

52,5cm

>30cm

>43cm

52,5cm

>50cm

52,5cm

>50cm

>43cm

 >30cm

>30cm

>30cm

31cm

31cm

Kamin

Anschluss

Kamin

Anschluss

Kamin

Anschluss

43cm

>64cm

>84cm

72cm

>64cm

43cm

Note

For any type of flue connection, the total height of the inner space must be a minimum of 140cm (Revivo 140), or 125cm (Revivo 125).

Summary of Contents for E15883

Page 1: ...REVIVO 140 REVIVO 125 Assembly instructions...

Page 2: ...he RIKA installation kit E16223 for installation Ask your local RIKA dealer for it Supply range of control panel variants E15886 consisting of Q Control panel flush mounting cover bracket flush mounti...

Page 3: ...hregeln des Ofen und Luftheizungsbauerhandwerks TR OL 2006 rules of the tiled stove and air heating system builder trade must be observed A supply air section of 200cm2 and a circulating air section o...

Page 4: ...th mm 525 T Corpus depth mm 663 H P Pellet filling height mm 1278 Flue pipe connection R Flue pipe outlet mm 100 RO H Rear connection height cm 96 RO S Rear connection side distance cm 31 RO T Top con...

Page 5: ...Width mm 525 T Corpus depth mm 663 H P Pellet filling height mm 1 235 Flue pipe connection R Flue pipe outlet mm 100 RO H Rear connection height cm 96 RO S Rear connection side distance cm 31 RO T To...

Page 6: ...on variants Preparing the control panel variants Flush mounted variant Wall mounted variant Note The floor clearance y1 respectively y2 must not exceed 1 3m The maximum distance between control panel...

Page 7: ...mounted For installation variant A LEFT SIDE flue connection or B REAR SIDE flue connection you need to interchange the flue pipe attachment and the blind cover Be sure of leak tightness Remove the f...

Page 8: ...ghtness Fasten the heat protection jacket to the flue collector using self tapping hex screws 4x Connect the flue pipe to your flue according to available connection possibilities Be sure of leak tigh...

Page 9: ...y Be sure that the On Off I O switch is in OFF O position and connect the power cable to the mains supply Note Be sure that no cable can touch a hot surface Adjusting the front panel Turn the lock scr...

Page 10: ...as been established again Wall mounted installation of control panel Connect the control panel cable to the touch display and fasten the wall mounting cover on the wall bracket using the magnets inclu...

Page 11: ...11 EN 10 Your notes...

Page 12: ...etting and printing errors reserved 2017 RIKA Innovative Ofentechnik GmbH Z37509_REVIVO_Montage_EN 7 09 2017 RIKA Innovative Ofentechnik GmbH M llerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686...

Reviews: