background image

RIGOL 

 

   

 

 

II               

DS2000  Service Guide 

Safety Requirement 

 

General Safety Summary 

 

Please review the following safety precautions carefully before putting the instrument 

into operation so as to avoid any personal injuries or damages to the instrument and 

any product connected to it. To prevent potential hazards, please use the instrument 

only specified by this manual. 

 

Use Proper Power Cord.

 

Only the power cord designed for the instrument and authorized by local country 

could be used. 

 

Ground The Instrument.

 

The instrument is grounded through the Protective Earth lead of the power cord. To 

avoid electric shock, it is essential to connect the earth terminal of power cord to the 

Protective Earth terminal before any inputs or outputs. 

 

Connect the Probe Correctly.

 

Do not connect the ground lead to high voltage since it has the isobaric electric 

potential as ground.

 

 

Observe All Terminal Ratings.

 

To avoid fire or shock hazard, observe all ratings and markers on the instrument and 

check your manual for more information about ratings before connecting.

 

 

Use Proper Overvoltage Protection.

 

Make sure that no overvoltage (such as that caused by a thunderstorm) can reach the 

product, or else the operator might expose to danger of electrical shock.

 

 

Do Not Operate Without Covers.

 

Do not operate the instrument with covers or panels removed.

 

 

Use Proper Fuse.

 

Please use the specified fuses. 

 

Avoid Circuit or Wire Exposure. 

Do not touch exposed junctions and components when the unit is powered. 

 

Do Not Operate With Suspected Failures. 

If you suspect damage occurs to the instrument, have it inspected by qualified service 

personnel before further operations.

 

Any maintenance, adjustment or replacement 

especially to circuits or accessories must be performed by 

RIGOL

 authorized 

personnel. 

 

Summary of Contents for DS2000 Series

Page 1: ...RIGOL Service Guide DS2000 Series Digital Oscilloscope Feb 2014 RIGOL Technologies Inc...

Page 2: ......

Page 3: ...OL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this...

Page 4: ...ead to high voltage since it has the isobaric electric potential as ground Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instrument and check your m...

Page 5: ...damages to the device or personal injuries it is important to operate the device away from an explosive atmosphere Keep Product Surfaces Clean and Dry To avoid the influence of dust and or moisture in...

Page 6: ...t could result in damage to this product or other property Terms on the Product These terms may appear on the Product DANGER indicates an injury or hazard may immediately happen WARNING indicates an i...

Page 7: ...eform can be recorded 56 Mpts maximum memory depth option and 14 Mpts standard memory depth 256 degree gray scale display Low noise 500 V div to 10 V div ultra wide vertical dynamic range 8 0 inches W...

Page 8: ...he Instrument 1 2 Disassemble the Rear Cover 1 3 Disassemble the Rear Metal Cover 1 4 Disassemble the Fan 1 5 Disassemble the Power Module 1 6 Disassemble the Front Panel and Knobs 1 7 Disassemble the...

Page 9: ...lease wear anti static wrist strap or make other anti static precaution when disassembling the instrument Please use proper tools and follow the correct steps Take care not to deform the metal structu...

Page 10: ...trument When disassembling or assembling the instrument please follow the procedures and take care not to scratch the surfaces of the parts The recommended disassemble procedures are as follows Disass...

Page 11: ...e handle groove 2 screws PM SW FW3 8 torx pan head screw assembly one on the inner side of the left and right supporting legs respectively at the supporting legs at the bottom of the cover Dsiassemble...

Page 12: ...ur on the top and bottom respectively fixing the front metal panel and rear metal cover Disassemble Steps 1 Remove the 8 screws fixing the front metal panel and rear metal cover using the screw driver...

Page 13: ...4 screws PTF5 10 torx countersunk head self tapping screw fixing the fan Disassemble Steps 1 Remove the 4 screws fixing the fan using the screw driver T10 Tip Pay attention to the direction of the fan...

Page 14: ...cover 4 screws PM SW FW3 6 torx pan head screw assembly fixing the power module note that one screw is not marked out in the figure Disassemble Steps 1 Remove the 4 screws fixing the power cover usin...

Page 15: ...ad screw assembly fixing the front panel Dsiassemble Steps 1 Remove the 9 knobs 2 Remove the 9 screws fixing the front panel using the screw driver T10 3 Take off the front panel gently Tip When remov...

Page 16: ...g the main keyboard Disassemble Steps 1 Remove the 2 screws fixing the left keyboard using the screw driver T10 2 Remove the 5 screws fixing the main keyboard using the screw driver T10 3 Remove the l...

Page 17: ...emble the LCD Figure 1 8 Disassemble the LCD Part Explanation 4 screws nichel plated FM3 6 C1018 torx countersunk head screw fixing the LCD Disassemble Steps Remove the 4 screws fixing the LCD using t...

Page 18: ...nation 1 screw M3 6 pan head torx fixing the top key support Disassemble Steps 1 Remove top key clip soldered onto the top key board 2 Remove the top key spacer top knobs and top key board in order 3...

Page 19: ...ps 1 Remove the 15 screws fixing the main board and front metal panel using the screw driver T10 2 Remove the 3 nuts and washers at the BNC port at the front metal panel using the BNC socket and the 5...

Page 20: ...assemble procedures Check whether the cables are correctly connected and whether all the screws are installed after each step of assemble You are recommended to follow the order and method introduced...

Page 21: ...C namely channel connector 3 Check whether the probe is correctly connected to the item to be tested 4 Check whether there are signals generated from the item to be tested you can connect the probe co...

Page 22: ...USB Check the IO Setting in Utility to make sure whether the setting in USB Device matches the device currently connected If needed restart the oscilloscope 8 The USB storage device can not be recogn...

Page 23: ...on should be performed to ensure the accuracy of the performance 4 Arrange the instrument properly after you finish the operation of the instrument 5 Keep the relative accessories of the instrument pr...

Page 24: ...s To clean the exterior surface perform the following steps 1 Disconnect the instrument from all power sources 2 Clean the loose dust on the outside of the instrument with a lint free cloth with a mil...