LG200 Owner's Manual
Cleaning – HVAC Filter
Page 43
MTS-T4-LG200-Owners-Manual-052815
Figure 26
– Main Unit
Main Unit General Cleaning
1. Wash the exterior of the main unit making sure that all louvered areas are
clear (this is especially important so that air may easily enter and exit the
APU).
2. Remove the front cover and gently wash the interior of the APU being
careful to keep sprayer 2 feet (24 inches) from any component.
3. Before replacing the front cover you will have to spray all electrical
connections & sensors to prevent the connections & sensors from corroding.
Make sure the engine compartment is dry first. Using battery sealant, spray
the positive & negative post, glow plugs, and run solenoid.
(see Figure 26 for areas to spray with battery sealant).
Battery
Posts
High
Temperature
Sensor
Low Oil
Pressure
Sensor
Glow Plugs
Binary
Switch
Run Solenoid