01-05-2017
3
On multiple cartridge tools, use the up and down arrows to navigate to the tool pocket
that the cartridge is being fitted to. Note that cartridge 1 is always located furthest from
the shank.
Enter the cartridge serial number (ID) that is etched on its side, then press SEL twice to
initiate the data upload.
After a few seconds the handset will establish a wireless connection with the tool. A
confirmation message is displayed when the upload is complete.
Note: It is important to regularly update the cartridge database on the SD card. The
most recent version can be downloaded from the Rigibore website using the link below.
It is essential to do this if new cartridges have been purchased or after a
cartridge has been repaired
.
http://rigibore.com/ActiveEdge/CalibrationFiles/HandyCDF.dbf
Switch off tool
Shuts down the tool completely to conserve battery power if the tool is not
being used for several days.
Enter the tool ID and press SEL twice to start the tool shutdown process.
Within a few seconds the handset will establish a wireless connection with the tool, then
display a message confirming that the tool has shut down completely. The tool must be
manually switched on before it can be used again.
Odometer
Shows the number of adjustment sessions carried out by the tool during its
lifetime.
ActiveEdge tools maintain a record of how often they have completed a compensation
session. This information can be accessed by entering the tool ID and pressing SEL
twice.
Within a few seconds the handset will establish a wireless connection with the tool. The
information is displayed when the process is complete.