background image

 

 

 

If the program could not detect the analyzer, check whether Bluetooth is enabled in the analyzer (1 mode in 
the Settings menu) and whether Bluetooth is enabled on your smartphone/tablet. 

Charging the analyzer.

 

The 

Stick 230 analyzer

 is powered by a 

18650 Li-ion

 battery. The analyzer comes with a

 2800 mAh

 battery. 

The analyzer can be charged from a PC. According to the specification, when connecting the analyzer to the 
USB 2.0 connector, the maximum charge current is 0.5 A. When connecting the analyzer to the USB 3.0 
standard connector, the maximum charge current is 0.9 A. 

The analyzer for charging can be connected to any charger (for phones/tablets) with an output voltage of 5 
volts and a current of at least 0.5 A. 

The maximum charge current of the analyzer is 1 A. 

The time for a full charge of a battery with a capacity of 2800 mAh (from 0 to 100%) is about 

3 hours

 (when 

using a charger). 
During charging, the bottom of the analyzer near the USB connector may become slightly warm. This is not a 
malfunction. 

During charging in the off state, the lightning icon is displayed on the analyzer screen. 

During charging, when the analyzer is on, the 

CHG

 icon will be displayed at the top of the screen. If the 

charge occurs with a current of 1 A, then, in this case, the 

FAST

 icon is additionally displayed. For example, a 

screenshot of the screen of the analyzer charged from the charger: 

 

Summary of Contents for Stick 230

Page 1: ...C Bluetooth Availability Yes Bluetooth ver 4 2 BLE Single mode Class B Battery Charge Time 3 hours RF Power 10 dBm at 50 Ohm load Minimum frequency step 1 kHz Operating temperature 0 40 C 32 104 F Tu...

Page 2: ...ing measurement mode On the fifth screen when you press the key you will enter the Settings menu The Single mode Single is a measurement of all parameters The mode is started by pressing the key After...

Page 3: ...will change continuously with an accelerated step pressing and holding the key for 2 seconds After that an information window will appear on the analyzer screen Press key again A window will appear on...

Page 4: ...he key will bring up the Help menu HAM mode This mode allows you to measure and display the SWR antenna chart on the analyzer screen on one of the fixed HAM radio bands such as 2 2 km 630 m 160 m 80 m...

Page 5: ...out of range but very close to the beginning or end In such cases the analyzer will determine the resonance beyond the limits of the ranges When you press the or keys the analyzer switches to Free mo...

Page 6: ...ing the key will cause an accelerated continuous change in frequency long press After press a window will be available with a choice of setting the center frequency exit or calling Help Press briefly...

Page 7: ...e value Available values 12 5 Ohm 25 Ohm 28 Ohm 37 Ohm 50 Ohm 75 Ohm 100 Ohm 150 Ohm 200 Ohm 300 Ohm 450 Ohm 600 Ohm Default 50 Ohm This setting is needed in cases where for example when measuring a b...

Page 8: ...The Stick 230 analyzer together with AntScope for Android works with smartphones and tablets running Android version 6 and higher You can download AntScope for Android directly on Google Play https pl...

Page 9: ...or charging can be connected to any charger for phones tablets with an output voltage of 5 volts and a current of at least 0 5 A The maximum charge current of the analyzer is 1 A The time for a full c...

Page 10: ...xternal charger The Stick 230 analyzer is protected against battery polarity reversal An incorrectly installed battery will not cause damage to the analyzer and when the charger is connected the analy...

Reviews: