background image

 

 Singe   Multé 

 

 HAM    Free 

 

The 

Singe

 and 

Multé

 functions display the measurement result as numbers, while the 

HAM

 and 

Free

 functions 

display the measurement results as numbers and charts. 

When you press 

  in the 

Main Menu

, 5 information screens will be available. 

The first four screen will briefly talk about the main measuring functions of the analyzer (

Single, Multé, HAM, 

Free

). By pressing the 

 key, you can switch to the corresponding measurement mode. 

On the fifth screen, when you press the 

 key, you will enter the 

Settings menu.

 

 

The Single mode.

 

Single

 is a measurement of all parameters. The mode is started by pressing the  

  key. 

After pressing the key, the measurement will start automatically. This is indicated by a flashing antenna icon 

located at the top of the screen. You can stop the measurement by pressing 

 once. You can resume the 

measurement by pressing  

 once. 

In 

Single mode

, the analyzer has 5 screens with information. 

The first screen displays: 

 

working frequency 

 

SWR

 value 

 

return loss value 
The second screen displays: 

 

working frequency 

 

|Z|

 value 

Summary of Contents for Stick 230

Page 1: ...C Bluetooth Availability Yes Bluetooth ver 4 2 BLE Single mode Class B Battery Charge Time 3 hours RF Power 10 dBm at 50 Ohm load Minimum frequency step 1 kHz Operating temperature 0 40 C 32 104 F Tu...

Page 2: ...ing measurement mode On the fifth screen when you press the key you will enter the Settings menu The Single mode Single is a measurement of all parameters The mode is started by pressing the key After...

Page 3: ...will change continuously with an accelerated step pressing and holding the key for 2 seconds After that an information window will appear on the analyzer screen Press key again A window will appear on...

Page 4: ...he key will bring up the Help menu HAM mode This mode allows you to measure and display the SWR antenna chart on the analyzer screen on one of the fixed HAM radio bands such as 2 2 km 630 m 160 m 80 m...

Page 5: ...out of range but very close to the beginning or end In such cases the analyzer will determine the resonance beyond the limits of the ranges When you press the or keys the analyzer switches to Free mo...

Page 6: ...ing the key will cause an accelerated continuous change in frequency long press After press a window will be available with a choice of setting the center frequency exit or calling Help Press briefly...

Page 7: ...e value Available values 12 5 Ohm 25 Ohm 28 Ohm 37 Ohm 50 Ohm 75 Ohm 100 Ohm 150 Ohm 200 Ohm 300 Ohm 450 Ohm 600 Ohm Default 50 Ohm This setting is needed in cases where for example when measuring a b...

Page 8: ...The Stick 230 analyzer together with AntScope for Android works with smartphones and tablets running Android version 6 and higher You can download AntScope for Android directly on Google Play https pl...

Page 9: ...or charging can be connected to any charger for phones tablets with an output voltage of 5 volts and a current of at least 0 5 A The maximum charge current of the analyzer is 1 A The time for a full c...

Page 10: ...xternal charger The Stick 230 analyzer is protected against battery polarity reversal An incorrectly installed battery will not cause damage to the analyzer and when the charger is connected the analy...