RigExpert AA-35 ZOOM
Display all parameters
To display various parameters of a load
on a single screen, press the
(All)
key.
Do not be confused by negative values of L or C. This can be useful for
experienced users.
This screen displays values for
series as well as parallel models
of impedance of a load.
11
• In the
series
model, impedance is
expressed as resistance and reactance
connected in series:
• In the
parallel
model, impedance is
expressed as resistance and reactance
connected in parallel:
R
X
Z = R + jX
R
X
Z = R ||+ jX
Summary of Contents for AA-35 ZOOM
Page 1: ...AA 35 ZOOM RigExpert User s manual Antenna and cable analyzer...
Page 2: ......
Page 23: ...RigExpert AA 35 ZOOM 23...