RF602 [Revision 1.2.0] 28.01.2019
Laser Triangulation Sensors. RF602 Series
7
Figure 2
8.2. Overall demands for mounting
The sensor is positioned so that the object under control has to be placed in the
working range of the sensor. In addition, no foreign objects should be allowed to stay on the
path of the incident and reflected laser radiation.
Where the objects to be controlled have intricate shapes and textures, the incidence
of mirror component of the reflected radiation to the receiving window should be minimized.
9. Connection
Assignment of the cable wires is shown in the table below:
Model of the
sensor
Pin number
Assignment
Wire color
232-U/I-IN-AL
free lead
free lead
DB9
DB9
free lead
free lead
free lead
DB9
-
-
2
3
-
-
-
5
Power U+
Gnd (power)
TXD
RXD
U/I
IN
AL
Gnd (common for signals)
Red
Brown
Green
Yellow
Blue
White
Pink
Gray
485-U/I-IN-AL
free leads
Power U+
Gnd (power)
DATA+
DATA-
U/I
IN
AL
Gnd (common for signals)
Red
Brown
Green
Yellow
Blue
White
Pink
Gray