Wheel diameter measuring gauge, IDK
IDK [Revision 2.2] 4th September 2017
7
Press
Red
button to reset averaging result at switching to another wheel.
For viewing the result of measurement with indication discreteness
0.01mm
(it is
accessible only in a mode of direct indication) it is necessary to press
Blue
button, thus
displayed result will be shifted to the left on one digit. Next pressing
Blue
button will lead
to return of indication to a starting position.
9.4.
Gauge turn-out
The gauge turn-out occurs automatically. The display extinguishes if there were
no buttons pressings for 60 seconds, at that only blinking dot is shown. If there were no
button pressings for 4 more minutes, the gauge is turned out completely. You can turn
the gauge off by long pressing
Red
button (more then 3 sec.).
10. Indication parameters setup
10.1. Image rotation
To rotate the image it is necessary to:
turn the power on (press
Red
button);
press
Blue
button and keep it pressed for more than three seconds;
display will show “Up”;
by the pressing of
Green
button turn o
ver the image: the message “
Up
” will
be turned over 180
0
;
to save the changed parameters press
Red
button. The display shows
“
SAUE
” message, press the
Green
button to confirm saving and
Red
to can-
cel saving of the changed parameters;
Image rotation function allows observing the result in the way comfortable for the
operator regardless of the gauge placement direction.
Notes:
- indication discreteness of
0.01mm
is accessible only in a mode of direct indica-
tion;
Summary of Contents for IDK Series
Page 1: ......