SWITCHING RIFT® 200 

ON

’ 

(CONTINUED)

 

This is achieved on the RIFT® 200 by a single press & hold of the Auto/Manual Touch Pad until the Red LED 
illuminates & flashes Red (8 O

clock position) and then touching either the open or close pads will send the 

actuator towards that position whilst the touch pads are engaged or a double tap will complete the move 
or move the actuator fully to the opposite position;

 

 

If external power is available and a remote command signal is being received (Auto), the actuator will 
respect the remote command signal being applied and if not already in the commanded position, and 
will move to it. If the actuator has been put into local control (Manual –

 

RED Flashing LED illuminated at 

the 8 O'clock position) the local commands override the remote command signal and the actuator will 
move to that selected position whilst the Open/Close Pads are pressed. The actuator will not accept 
remote command signals until the actuator is put back into the remote command mode (Auto –

 

RED 

FLASHING LED at the 8 O

clock position extinguished)

 

When the actuator is released from local control (Manual) the actuator will revert back to the last or 
selected remote command position or Powered Position if no command given.

 

When mains power is unavailable, an internal trickle charged Li

-

Ion battery, supplied with the actuator, 

provides internal power to allow use of the Touch Pads to open or close the actuator relative to the 
Pad being pressed. On releasing the Pad, the actuator will stay put, on resumption of external power 
the actuator will remain in local manual control and not move to the remote command position until 
the Auto/Manual Touch Pad is pressed to release the actuator from this overriding control position       
returning the actuator to normal remote control selected position.

 

If 

it is 

essential 

that the actuator moves to a pre

-

determined position upon external power           

failure, 

you must 

select and configure the RIFT® 200 actuator for 

FAILSAFE

’ 

functionality. 

 

 

Auto/Manual Touch Pad selected (RED Flashing LED at the 8 O

clock position) for EMERGENCY HAND      

OPERATION is as follows; 

 

If the actuator is OPEN with an open signal applied, this will have no effect, but pressing the CLOSE Pad it 
will start the actuator to rotate in a Clockwise (CW) direction and the RED LEDs will rotate in the direction 
of movement, and when the CLOSE Pad is released, the actuator will stop in its current position and two 
LED

s will be displayed to show the approximate position of the actuator.  Press the OPEN Pad and the 

actuator will move in a Counter Clockwise (CCW) direction and the LEDs will display Green. If the actuator 
is  CLOSED  with  a  Close  signal  applied,  this  will  have  no  effect,  but  pressing  the  OPEN  Pad  will  start  the       
actuator to rotate in a CCW direction and the GREEN LEDs will rotate in the direction of movement, and 
when  the  OPEN  Pad  is  released,  the  actuator  will  stop  in  its  current  position  and  two  LED

s  will  be  dis-

played to show the approximate position of the actuator. Press the Close Pad and the actuator will move 
in a CW direction and the LEDs will display Red.

 

 

Start position

 

Command signal applied

 

LED Status

 

OPEN

 

CLOSE

 

 

 

 

 

 

 

 

 

 

Rotates CW until arrives at the Closed 
position or movement is stopped

 

 

 

 

 

 

 

              Closed Position.

 

CLOSED

 

OPEN

 

 

 

 

 

 

Rotates CCW until arrives at the Open 
position or movement is

 

stopped

 

 

 

 

 

 

 

               Open Position.

 

Summary of Contents for RIFT 200

Page 1: ...1 VERSION 1 1 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS Large RIFT 200 Nm...

Page 2: ...OLENOID 7 CONFIGURING AS A MULTI TURN ACTUATOR 8 CONFIGURING AS A MULTI TURN ACTUATOR CONTINUED 8 CONFIGURATION AND CONNECTION WITH ANDROID 8 PAIRING RIFT ACTUATOR WITH ANDROID 8 RUNNING THE ANDROID A...

Page 3: ...ILURE TO OPERATE 18 OVER TORQUE INDICATION 18 3 WAY BALL VALVES DEFAULT FLOW PATTERNS 19 3 WAY BALL VALVES DEFAULT FLOW PATTERNS CONTINUED 19 BLUETOOTH 19 BATTERY FAILSAFE FUNCTION BFS 20 METHOD OF OP...

Page 4: ...operation and that non adherence to the warnings WILL result in product failure and potential personal injury and or consequential damage STORAGE Store in a well ventilated and dry room Actuators shou...

Page 5: ...n from the valve s ISO 5211 platform to the top of the stem or shaft does not exceed the maximum depth of the female drive output to be used as this will push the actuator s internal components upward...

Page 6: ...for the Closed position and adjust it as so PROCEDURE TO USE CALIBRATION MODE TO MOUNT TO A F07 F10 FLANGE a Move the actuator to the closed position b Mount the RIFT 200 actuator onto the valve usin...

Page 7: ...el confirmation local controls and torque protection and as an extra cost option speed control Note Thermostatic Anti condensation Heaters These are only supplied from the external power supply if thi...

Page 8: ...ngs Bluetooth identify under Available Devices e g SACO3 070317 1177 select the Actuator you wish to pair with Enter the default pairing code 1234 the actuator should be displayed under the Paired Dev...

Page 9: ...TTING Firmware Version Displays the version of the firmware flashed onto the RIFT 200 App Version Displays the version of the App you are running Valve Orientation Set the valve orientation of the val...

Page 10: ...to Torque Limit Back off allows the user to specify the angle that the actuator will back off if the Torque Limit is reached The RIFT 200 will display an Orange on the top indicating that the Torque...

Page 11: ...ll feed back the actual RIFT 200 Actuator position in either 0 10v or 0 4 20mA respective to the control signal input Volt free switch connection is connected through pin 1 0 10v and pin 2 0 10v on th...

Page 12: ...t easily assessable We advise additional external battery storage is available to prolong operations on a predetermined cycle WIGGLE This function will allow the RIFT 200 Actuator to be programmed to...

Page 13: ...ins 1 4 See page 15 for wiring diagram Follow the wiring diagram appropriate to your functional requirement to ensure the correct connection of power and control signaling to the RIFT 200 actuator DO...

Page 14: ...fe we recommend either a single multicore cable on 10 pin connector supplied is used via the left entry and the right entry connected with 5 core cable onto the 5 pin connection block fitted for the c...

Page 15: ...etting adjustments Soft reset of the electronics similar to the Ctrl Alt Del under Basic Settings option on the Android App only Reset Board Without Changing Settings this will re set the board and an...

Page 16: ...art functioning as an ON OFF part turn electric actuator It could be required in an emergency to be able to move the RIFT 200 actuator independent of the external remote control signal This is achieve...

Page 17: ...manual control and not move to the remote command position until the Auto Manual Touch Pad is pressed to release the actuator from this overriding control position returning the actuator to normal rem...

Page 18: ...s not only to protect the actuator but also the valve is fitted onto within its operational torque bands If the maximum torque is exceeded through either blockage or trying to exceed the operational d...

Page 19: ...use immediately You can test the changes where applicable by selecting using the relevant buttons on the screen of your Bluetooth device e g OPEN and clicking or physically touching the Pad on the RI...

Page 20: ...AL CONTROL FUNCTION Electronic Positioning System EPS The RIFT 200 can be Bluetooth configured to select modulating control see page 9 for using Bluetooth with the RIFT 200 For modulating control chec...

Page 21: ...will not control the movement of the Valve Actuator when Analogue Signal Control is selected this is primarily used as a charging circuit Unnecessary frequent movement instigated by a constantly fluct...

Page 22: ...ware Updates and or New Features DEFINITIONS ABBREVIATION Definitions Abbre viation Explanation AC Alternating Current DC Direct Current PCD Pitch Circle Diameter LCM Local Control Mode PID Proportion...

Page 23: ...23 DOCUMENT REVISION TABLEDOCUMENT REVISION TABLE Date Name Revision Details 24 10 2019 Brown 1st revision for large and Android App 06 05 2020 Fabio Musio Changed literature to RIFT Actuators...

Reviews: