Information and general instructions

2.1

Information about the instruction manual

2.1.1

Introduction

The instruction manual supplied with the burner:

is an integral and essential part of the product and must not
be separated from it; it must therefore be kept carefully for
any necessary consultation and must accompany the burner
even if it is transferred to another owner or user, or to
another system. If the manual is lost or damaged, another
copy must be requested from the Technical Assistance
Service of the area;

is designed for use by qualified personnel;

offers important indications and instructions relating to the
installation safety, start-up, use and maintenance of the
burner.

Symbols used in the manual

In some parts of the manual you will see triangular DANGER
signs. Pay great attention to these, as they indicate a situation of
potential danger.

2.1.2

General dangers

The 

dangers

 can be of 

3 levels

, as indicated below.

2.1.3

Danger: live components

Other symbols

Abbreviations used

Ch.

Chapter

Fig.

Figure

Pag.

Page

Sec.

Section

Tab.

Table

Delivery of the system and the instruction manual

When the system is delivered, it is important that:

The instruction manual is supplied to the user by the system
manufacturer, with the recommendation to keep it in the
room where the heat generator is to be installed.

The instruction manual shows:
– the serial number of the burner;

– the address and telephone number of the nearest Assist-

ance Centre.

The system supplier carefully informs the user about:
– the use of the system, 
– any further tests that may be necessary before the system

is started up, 

– maintenance and the need to have the system checked at

least once a year by the manufacturer or another special-
ised technician.
To ensure a periodic check, the manufacturer recom-
mends the drawing up of a Maintenance Contract.

2

Information and general instructions

DANGER

Maximum danger level!
This symbol indicates operations which, if not car-
ried out correctly, cause serious injury, death or
long-term health risks.

WARNING

This symbol indicates operations which, if not car-
ried out correctly, may cause serious injury, death
or long-term health risks.

CAUTION

This symbol indicates operations which, if not car-
ried out correctly, may cause damage to the ma-
chine and/or injury to people.

DANGER

This symbol indicates operations which, if not car-
ried out correctly, lead to electric shocks with le-
thal consequences.

ENVIRONMENTAL PROTECTION

This symbol gives indications for the use of the
machine with respect for the environment.

This symbol indicates a list.

.........................................................................................

.........................................................................................

.........................................................................................

.........................................................................................

Summary of Contents for RS 650/E BLU

Page 1: ...27770 4 04 2012 Installation use and maintenance instructions Gas burner Quemador de gas Modulating operation Funcionamiento modulante CODE C DIGO MODEL MODELO TYPE TIPO 20026361 RS 650 E BLU 1122T1 G...

Page 2: ......

Page 3: ...SQM48 4 15 5 Installation 16 5 1 Notes on safety for the installation 16 5 2 Handling 16 5 3 Preliminary checks 16 5 4 Operation position 17 5 5 Removal of the locking screws from the shutter 17 5 6...

Page 4: ...as pressure switch 28 6 8 4 Pressure switch PVP kit 28 6 9 Burner operation 29 6 9 1 Normal firing 29 6 9 2 No firing 29 6 9 3 Burner flame goes out during operation 29 6 9 4 Troubleshooting 29 7 Main...

Page 5: ...2006 42 CE Machine Directive LVD 2006 95 CE Low Voltage Directive EMC 2004 108 CE Electromagnetic Compatibility Such products are marked as follows The quality is guaranteed by a quality and managemen...

Page 6: ...ual is supplied to the user by the system manufacturer with the recommendation to keep it in the room where the heat generator is to be installed The instruction manual shows the serial number of the...

Page 7: ...d and or not working installation of untested supplementary components on the burner powering of the burner with unsuitable fuels faults in the fuel power supply system use of the burner even followin...

Page 8: ...th the burner components is not allowed apart from the parts requiring maintenance Only those parts envisaged by the manufacturer can be replaced 3 2 Personnel training The user is the person body or...

Page 9: ...tem 3 400 50 3 230 50 Auxiliary voltage 230 50 60 110 50 60 R LS 650 E TC Emission Class 1 EN267 EN676 MY Class 1 EN267 Class 3 EN676 BLU Class 3 EN267 EN676 MX Class 2 EN267 Class 3 EN676 FS1 3 400 5...

Page 10: ...253 552 Fuel Natural gas G20 methane G21 G22 G23 G25 Gas pressure at maximum delivery 2 Gas G20 G25 mbar 58 86 5 Operation Continuous Intermittent Standard applications Boilers water steam diathermic...

Page 11: ...t inspection of the combustion head requires the burner to be opened by rotating the rear part on the hinge The overall dimensions of the burner when open are indicated by L and R Position I is a refe...

Page 12: ...mber dimensions are clearly smaller than those indicated in diagram Fig 4 consult the manufacturer The firing rates were set in relation to special test boilers accord ing to EN 676 regulations Fig 4...

Page 13: ...r movement of combustion head 17 Gears for movement of air damper 18 Air pressure switch 19 Air pressure test point 20 Maximum gas pressure switch with pressure test point 21 UV sensor 22 Hinge for op...

Page 14: ...0 Air pressure switch NOTE Two types of burner failure may occur Flame control lockout the signal light 12 Fig 6 on the panel advises that the burner is lockout To reset press the button 12 Fig 6 Moto...

Page 15: ...lso be observed Condensation and ingress of humidity must be avoided Should such conditions occur make sure that the unit will be completely dry before switching on again Static charges must be avoide...

Page 16: ...tdown from operating position at mains voltage Restart on rise in mains voltage AC 186 V AC 188 V Oil pump magnetic clutch nominal voltage Nominal current Output factor 2A cos 0 4 Air pressure switch...

Page 17: ...tional low voltage section The holding torque is reduced when the actuator s power sup ply is switched off The housing cover may only be removed for short periods of time for wiring or when making the...

Page 18: ...ith the standards and regula tions of the laws in force WARNING The handling operations for the burner can be highly dangerous if not carried out with the great est attention keep any unauthorised peo...

Page 19: ...ith the burner 5 6 2 Blast tube length The length of the blast tube must be selected according to the in dications provided by the manufacturer of the boiler and in any case it must be greater than th...

Page 20: ...ith the screws given as standard equipment 5 8 Accessibility to the interior of the combustion head Open burner at hinge as illustrated in Fig 14 after releasing the tie rod of the head movement lever...

Reviews: