Riello NetMan User Manual Download Page 4

ENGLISH 

INTRODUCTION 

Thank you for choosing our product. 
The accessories described in this manual are of the highest quality, carefully designed and 
built in order to ensure excellent performance. 
This manual contains detailed instructions on how to install and use the product. 
It should be kept with care near the device, so that it can be consulted for information on 
how to use and make the most of your device. 

IT SHOULD BE READ BEFORE YOU 

START WORKING ON THE DEVICE

 
 

SAFETY 

This part of the manual contains SAFETY precautions that must be followed 
scrupulously. 

The device has been designed to operate only in closed environments. It should be 
installed in rooms where there are no inflammable liquids, gas or other harmful 
substances. 
Take care that no water or liquids and/or foreign bodies fall into the device. 
In the event of a fault and/or impaired operation of the device, do not attempt to repair it 
but contact the authorized service centre. 
The device must be used exclusively for the purpose for which it was designed. Any other 
use is to be considered improper and as such dangerous. The manufacturer declines all 
responsibility for damage caused by improper, wrong and unreasonable use. 
 
© No part of this manual may be reproduced without the prior written permission of the 
manufacturer. 
The manufacturer reserves the right to modify the product described in this manual at any 
time and without notice. 

Summary of Contents for NetMan

Page 1: ...N e t M a n S e n s o r I n t e r f a c e 1 W i r e 4 C h a n n e l A D c o n v e r t e r User s Manual ...

Page 2: ......

Page 3: ...L DATA 5 INPUT 5 CONNECTIONS 5 CABLE SPECIFICATIONS 6 INSTALLATION 6 NETMAN PLUS JUMPER SETTINGS 6 CONNECTION OF THE SENSORS TO THE NETMAN PLUS 7 PHISICAL INSTALLATION OF THE DEVICE 8 SOFTWARE SETUP 9 IRRADIANCE SENSOR APPLICATION 10 ...

Page 4: ...te only in closed environments It should be installed in rooms where there are no inflammable liquids gas or other harmful substances Take care that no water or liquids and or foreign bodies fall into the device In the event of a fault and or impaired operation of the device do not attempt to repair it but contact the authorized service centre The device must be used exclusively for the purpose fo...

Page 5: ... for daisy chain connection Picture 2 Picture 3 Picture 5 a Jack connector Picture 3 to add an external power supply and two removable terminal blocks Picture 1 for an easier connection of the analog channels Picture 4 Picture 2 1 Wire ports DC power supply output Analog inputs Picture 1 Removable terminal blocks Picture 3 Jack and RJ12 connectors 1 5V 2 GND 3 Data 4 GND 5 N C 6 N C RJ 12 plug Pic...

Page 6: ...Number of devices must be less or equal than 6 where this device counts 2 The cable used must be shielded and only one end of the shield should be tied to protection earth PE Picture 6 netman to sensor interface Picture 7 sensor to sensor cable INSTALLATION NETMAN PLUS JUMPER SETTINGS In order to use the environmental sensors please configure the JP6 and JP10 jumpers as shown below See also the Ne...

Page 7: ...aded spacers and the chassis of the UPS Solar inverter Before connecting the sensors is therefore necessary to fix the DB9 spacers and the tooth lock washers supplied with the sensor as shown on the following image to fix the NetMan to the UPS Solar inverter with the supplied screws and tooth lock washers By means of a multimeter check the electrical continuity between the DB9 hexagonal threaded s...

Page 8: ...9 and Picture 10 rail or wall mounted Picture 11 1 2 3 1 Bolt 2 Washers 3 Nut Picture 8 assemble bolt Picture 9 lift the wings by means of a flat screw driver Picture 10 hang the device on a DIN rail and screw the bolts to secure the case to the rail Picture 11 Drill template for wall mount dimensions in mm ...

Page 9: ... Sensor Config menu Sensors Devices Press C to change sensors E to exit Sensors Devices 1 A D Converter 2600000013DF1E20 4 A D Converter 2 Dummy Press Y to confirm N to insert a new sensor STEP 3 Press C to force the NetMan to scan the 1 Wire bus for sensors STEP 4 2 out of 6 channels are occupied by this device hence a dummy placeholder device appears with the A D Converter Confirm the bus scan b...

Page 10: ...put 2 terminal GND on any of the available GND connections The supported input ranges for the sensor are 0 1200 W m2 and 20 80 C Please tie to PE the shield of the sensor s cable either on this device side or on transducer side not on both sides Once the setup described in the previous chapters is accomplished the Irradiance sensor values are available through the software SunVision please refer t...

Page 11: ......

Page 12: ......

Page 13: ... 15 INGRESSO 15 CONNESSIONI 15 SPECIFICHE DEI CAVI 16 INSTALLAZIONE 16 IMPOSTAZIONE DEI JUMPER 16 CONNESSIONE DEI SENSORI ALLA SCHEDA NETMAN PLUS 17 INSTALLAZIONE FISICA DEL DISPOSITIVO 18 IMPOSTAZIONI SOFTWARE 19 APPLICAZIONE SENSORE DI IRRAGGIAMENTO 20 ...

Page 14: ...avorare in ambiente interno Deve essere installato in stanze prive di liquidi o gas infiammabili o altre sostanze pericolose Prestare attenzione che all interno del dispositivo non finiscano acqua o corpi estranei Se dovesse verificarsi un guasto o se il dispositivo presentasse un funzionamento anomalo non tentare la riparazione Contattare un centro per il servizio di assistenza tecnica Il disposi...

Page 15: ...porte 1 Wire RJ12 per consentire una connessione in cascata di più dispositivi Figura 2 Figura 3 Figura 5 un connettore Jack per l alimentazione esterna Figura 3 e due morsettiere rimovibili Figura 1 per una connessioni più semplice degli ingressi analogici Figura 4 Figura 2 Porte 1 Wire Uscita alimentazione CC Ingressi analogici Figura 1 Connettori rimovibili Figura 3 Connettori Jack e RJ12 1 5V ...

Page 16: ...o di dispositivi in cascata è 6 Il presente dispositivo conta per 2 Il cavo usato deve essere schermato e solo una estremità del cavo deve essere connessa a terra Figura 6 cavo dalla scheda netman al sensor interface Figura 7 cavo tra sensori INSTALLAZIONE IMPOSTAZIONE DEI JUMPER Per usare I sensori ambientali configurare i jumper JP6 e JP10 come mostrato di seguito Consultare anche il manuale del...

Page 17: ...nteria dell UPS Inverter fotovoltaico Pertanto prima di collegare i sensori è necessario Fissare le torrette e le rondelle dentellate fornite in dotazione con il sensore come illustrato nell immagine seguente Fissare il NetMan all UPS Inverter fotovoltaico tramite le viti e le rondelle dentellate fornite in dotazione Con l ausilio di un multimetro verificare la continuità elettrica tra la torretta...

Page 18: ... 8 Figura 9 Figura 10 o montato a muro Figura 11 1 2 3 1 Bullone 2 Rondelle 3 Dado Figura 8 assemblare dado rondelle e bullone Figura 9 sollevare le alette con un cacciavite piatto Figura 10 agganciare il dispositivo alla barra DIN quindi stringere i dadi Figura 11 Maschera di foratura per il fissaggio a muro ...

Page 19: ...trare nel menù Sensor Config Sensors Devices Press C to change sensors E to exit Sensors Devices 1 A D Converter 2600000013DF1E20 4 A D Converter 2 Dummy Press Y to confirm N to insert a new sensor 3 Premere C per forzare la scheda NetMan ad eseguie una scansione del bus 1 Wire 4 Questo sensore occupa 2 dei 6 canali disponibili quindi assieme all A D converter è visualizzato anche un elemento fitt...

Page 20: ...qualunque delle connessioni GND disponibili Gli intervalli di misura suportati sono 0 1200 W m2 e 20 80 C Collegare a terra lo schermo del cavo del sensore dalla parte di questo dispositivo o dalla parte del trasduttore non da entrambe le parti Una volta completate le operazioni descritte nei precedenti capitoli i valori misurati sono resi disponibili attraverso il software SunVision fare riferime...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...0MNU147NPB ...

Reviews: