INSTALLER
24
1
°C
0
120
20
100
40
80
60
B
A
All the boiler’s internal electrical connections have been
pre-wired and tested in the factory.
Only the following connections are needed for installation.
- Connect the boiler to the mains power supply (single
phase 230V-50Hz) using the cable (1) from the rear of
the appliance.
- Connect up the room thermostat (TA) and the outdoor
temperature sensor (SE).
OUTDOOR TEMPERATURE SENSOR (SE) AND ROOM
THERMOSTAT (TA)
- Remove the front panels by pulling them forwards.
- Remove the two screws (A) and tilt the control panel (B)
downwards.
ELECTRICAL CONNECTIONS