PRECAUTIONS

GENERAL SAFETY INFORMATION

Do not allow children or 
infirm persons to operate 
the boiler unsupervised.

Do not operate any elec-
trical devices or equipment, 
including switches or domestic 
appliances, etc., if you can smell 
fuel or fumes. If you detect any suspicious smells:

- Ventilate the room by opening all doors and win-

dows.

-  Close the fuel shut-off cock.
-  Report the fault immediately to the 

r

 Technical 

Assistance Service or a professionally qualified 
heating engineer.

Never clean the boiler without first disconnecting it 
from the mains electricity supply by turning the main 
power switch OFF.

Never pull, disconnect, or twist the electrical cables 
coming from the boiler even if it is disconnected 
from the mains electricity supply.

Do no obstruct or restrict the vents in the room 
where the appliance is installed. Adequate ventila-
tion is essential for correct combustion.

Do not leave flammable substances or containers 
in the room where the boiler is installed.

Do not touch the boiler when 
barefoot or wet.

Do not switch the boiler off 
if outside temperature drops 
below ZERO (risk of free-
zing).

This instruction manual and that for the instal-
ler and Technical Assistance Service are integral 
parts of the boiler. They must be kept safe and 
must ALWAYS accompany the boiler, even if it is 
sold to another owner or user or transferred to ano-
ther installation. If you damage or lose this manual, 
order a replacement immediately from your local 

r

 Technical Assistance Centre.

The boiler must be installed 
by a legally qualified hea-
ting engineer. On comple-
tion of the installation, the 
heating engineer must 
issue the owner with a 
declaration of conformity 
confirming that the instal-
lation has been comple-
ted to the highest standards 

in 

compliance with the instructions provided by 

r

 

in this instruction manual, and that it conforms to all 
applicable laws and standards.

If you notice any water leaking from the boiler, 
disconnect it immediately from the mains electricity 
supply, shut off the water supply, and notify your 
local 

r

 Technical Assistance Centre or a quali-

fied heating engineer immediately.

Periodically check that ope-
rating pressure in the water 
circuit is 

over 1 bar

. If water 

pressure is consistently low, 
contact 

r

’s Technical 

Assistance Service or a pro-
fessionally qualified heating 
engineer.

If the boiler is not going to be used for an extended 
period of time, proceed as follows to prepare it for 
shut-down.

- Turn the mains power switch OFF.
- Close the fuel cock and heating circuit water cock.
- Drain the central heating circuit if there is any risk 

of freezing.

The boiler must only be used for the purpose spe-
cified by 

r

 and for which it is designed. The 

manufacturer declines all responsibility, contractual 
or other, for damage to property or injury to per-
sons or animals caused by improper installation, 
adjustment, maintenance or use.

The operation of any appliance that uses electrical power demands that a number of fundamental safety precautions 
be respected.

Summary of Contents for INSIEME CONDENS 26 B

Page 1: ...INSTRUCTION FOR THE USER CONDENSING BOILERS 26 B 26 BK 35 B 35 BK 26 BK 35 BK 26 B 35 B ...

Page 2: ...anual b Identifies actions that require caution and ade quate preparation a Identifies actions that you MUST NOT do CONTENTS General safety information 4 Precautions 4 Control panel 5 Start up 7 Temporary shutdown 10 Preparing for extended periods of disuse 10 Cleaning 11 Maintenance 11 Useful information 12 ...

Page 3: ...gularly by r s Technical Assistance Service Their personnel are specially trained to keep your boiler efficient and cheap to run Technical Assistance Centres also stock any original spare parts that might be required This instruction manual contains important instructions and precautions that must be observed to ensure the trouble free installation and efficient functioning of your boiler Please a...

Page 4: ...ose this manual order a replacement immediately from your local r Technical Assistance Centre bThe boiler must be installed by a legally qualified hea ting engineer On comple tion of the installation the heating engineer must issue the owner with a declaration of conformity confirming that the instal lation has been comple ted to the highest standards in compliance with the instructions provided b...

Page 5: ...rical power indicator Lights to show that the system is receiving electrical power 5 Burner lockout indicator Lights to show that a burner lockout has occurred 6 Manual reset for safety thermostat Allows you to reset the boiler if the safety thermostat trips Unscrew the protective cover to access the reset button 7 Function indicators 8 Manual reset for flue gas thermostat Allows you to reset the ...

Page 6: ... indicator Lights to show that a burner lockout has occurred 6 Summer I Winter II selector 7 Storage cylinder temperature gauge Displays the temperature of the domestic hot water 8 Manual reset for safety thermostat Allows you to reset the boiler if the safety thermostat trips Unscrew the protective cover to access the reset button 9 Storage cylinder thermostat Allows you to set the temperature of...

Page 7: ... check that the pressure in the heating circuit is over 1 bar but below the maxi mum limit specified for the boiler If water pressure is low contact r s Technical Assistance Service Set the room thermostat to the required temperature 20 C or if the system has a timer or temperature controller make sure that this is switched On and adjusted to the required temperature 20 C Turn the system s mains p...

Page 8: ...s before resetting the burner To reset the burner press the button light on the burner Wait for the burner to complete the entire start up cycle again up to the ignition of the flame IMPORTANT Before it starts pre ventilation pre purging the oil burner pre heats the fuel oil for about 2 and half minutes The first time the burner starts up for the winter ignition problems can occur if the temperatu...

Page 9: ...edly make sure that the flue gas vent pipe is not blocked and that the flue has been installed correctly bNo warning signal is given if the safety thermostat trips but the fact that is has tripped can be seen from the boiler temperature gauge T 110 C Proceed as follows to reset the safety thermostat Wait until boiler temperature falls below 80 C Remove the safety thermostat cover Press the manual ...

Page 10: ...ler thermostat to about the middle of the section with one line Turn the room thermostat to about 10 C or select the frost protection function If the boiler is not going to be used for an extended period of time proceed as follows to prepare it for shut down Turn the function selector to OFF I and make sure that the green power indicator goes out Turn the system s mains power switch OFF Close the ...

Page 11: ...aNever clean or service the boiler without first disconnecting it from the mains electricity supply by turning the main power switch OFF Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFESSIONALLY QUALIFIED PERSONNEL UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS r s Technical Assistance Service is qualified to satisfy these legal requir...

Page 12: ...eller Mr Address Tel Technical Assistance Service Mr Address Tel Fuel oil supplier Mr Address Tel Installer Mr Address Tel Date Work done Date Quantity supplied Date Quantity supplied Date Quantity supplied Date Quantity supplied ...

Page 13: ...USER 13 ...

Page 14: ...USER 14 ...

Page 15: ......

Page 16: ...Tel 0442630111 Fax 0442630371 www riello it As part of the company s ongoing commitment to perfecting its range of products the appearance dimensions technical data equipment and accessories may be subject to variation Cod 20042453 ...

Reviews: