9
USE
2
USE
2.1
Putting into service
Have the
R
Technical Assistance Service start-up your
GITRÈ
boiler for the first time. Once this has been done, the boiler can
be left to function automatically.
Under certain circumstances, such as after long periods of dis-
use, the user may need to re-start it without involving the Tech-
nical Assistance Service.
2.1.1
Preliminary operations
Perform the following checks before starting up the boiler:
− Check that the fuel shut-off cock and heating system
shut-off cock are open
− Check that the central heating circuit pressure gauge
shows a pressure over
1 bar
with the system cold. Check
also that the circuit is properly de-aerated
2.1.2
Start-up
Once you have completed all the checks listed above, proceed as
follows to start up the boiler for the first time:
ONLY FOR MODELS
GITRÈ 4
-
GITRÈ 5
-
GITRÈ 6
− Turn the boiler’s mains power switch ON
− Set the room thermostat to the required temperature (~
20°C) or, if the system has a timer or timer-thermostat,
make sure that this is switched “ON” and adjusted to the
required temperature (~ 20°C).;
− Open the control panel access door;
ONLY FOR MODELS
GITRÈ 4
-
GITRÈ 5
-
GITRÈ 6
− Turn the boiler thermostat to about the middle of the
section with three lines;
20
40
60
80
100
0
120
− Turn the function selector to ON (I) and make sure that
the green power indicator lights.
NOTE in the case of
GITRÈ 4
models, the burner only starts up
at the end of the fuel oil pre-heating phase.
20
40
60
80
100
0
120
The boiler now starts up and the burner remains lit until the
temperature setpoint is reached.
ONLY FOR GITRÈ B/100 MODELS
− Turn the boiler’s mains power switch ON;