11
USE
Proceed as follows to reset the safety thermostat:
− Wait until boiler temperature falls below 80°C;
− Open the control panel cover;
− Unscrew the cap over the safety thermostat reset button;
− Press the reset button;
− Replace the cap.
20
40
60
80
100
0
120
9
Eliminate the cause of overheating before restarting the
boiler. Contact
R
’s Technical Assistance Service.
2.2
Temporary shutdown
To switch the boiler off for short periods with outdoor temper-
ature ABOVE ZERO:
− Open the control panel access door;
− Turn the control panel power switch to (0) OFF and make
sure that the green power indicator goes out;
20
40
60
80
100
0
120
− switch the boiler OFF at the mains power switch;
9
Do NOT perform this procedure if outdoor temperature might
fall below ZERO (risk of freezing).
Then proceed as follows:
− Adjust the boiler thermostat to its minimum setting;
20
40
60
80
100
0
120
− Turn the room thermostat to about 10°C or select the frost
protection function.
ONLY FOR GITRÈ B/100 MODELS
− in addition to the previous operations, turn the storage
cylinder thermostat to about the middle of the section
with one line.
20
40
60
80
100
0
120