33
TECHNICAL DATA
13
TECHNICAL DATA
Detail
U.M.
Condexa Pro2 Evo IN-EXT
150
225
300
Certifications
Boiler typology
B23, B53, B53p, C13, C33, C53, C63
Overall dimensions and Connections
Height x Width x Depth
mm
1690x900x750
1690x1700x750
Loadless boiler weight
kg
250
350
380
Water capacity
l
70
112
132
Diameter Water connections
in
2” 1/2
Diameter gas manifold
in
2”
Diameter exhaust flue
mm
160
Diameter Condensate drain
mm
50
Power and efficiency
Heat power at burner rif. HS (min-max)
kW
16.6 ÷166.9
16.6
÷250.4
16.6 ÷333.9
Heat power at burner rif. HI (min-max)
kW
15 ÷ 150
15 ÷ 225
15 ÷ 300
Rated power supplied to water 100% (80 - 60°C)
kW
147.2
220.8
294.4
Rated power supplied to water 100% (50 - 30°C)
kW
162.2
243.3
324.4
Condensate production per hour 100% (50 - 30°C) with G20 gas
kg/h
22.4
33.6
44.8
Efficiency at rated power(80 - 60°C)
%
98.1
98.1
98.1
Efficiency at rated power (50 - 30°C)
%
108.1
108.1
108.1
Efficiency at min. power (80 - 60°C)
%
98.7
98.7
98.7
Efficiency at min. power (50 - 30°C)
%
109.2
109.2
109.2
Casing losses (Tm = 70°C)
%
0.1
0.1
0.1
Energy efficiency marking (Directive 92/42 EEC)
stelle
««««
Fuel and power supply
Categoria Gas
II2H3+
Consumo Gas Naturale (G20) (min / nominale)
m3/h
1.43 / 14.3
1.43 / 21.5
1.43 / 28.6
Alimentazione elettrica
230V - 50Hz
Potenza elettrica assorbita al 100%
KW
0.35
0.52
0.70
Combustion data
Max head fumes available to the exhaust
Pa
250
Carbon Monoxide CO (0% O2) (P min ÷ P max)
mg/kWh
23 ÷ 130
NOx class (secondo la EN 297)
5
Heating system
Heating temperature adjustment (min / max)
°C
20 / 80
Max/min working pressure
Bar
(kPa)
6 / 0.5
(600/50)
Pressure drop on the water side
∆
T 20°C
mbar
140
140
140
Residual water side
∆
T 20°C
mbar
150
150
150